– Connect the 8 mm or 10 mm diameter gas pipe to the regulator
outlet in accordance with the respective installation instructions for
olive screw connections (e.g. EN ISO 8434-1). When tightening,
carefully use a second spanner on the provided spanner surfaces to
keep the entire assembly from turning (surface (1)). Make sure that
the olive and the tapered seal are in perfect condition.
Figure 3
– Screw the outlet of the gas filter onto the regulator inlet, then se-
curely screw the high-pressure hose (with HRP) onto the inlet of
the gas filter. Make sure that the seals and thread are in perfect
condition.
Figure 4a
Figure 4b