Fuses
The 12 V fuse for the boiler is on the electronic control unit on
the appliance.
Figure 3
The fine wire fuse on the electronic control unit must
always be replaced with a fuse of the same type:
1.6 A (slow-acting), EN 60127-2-3.
Disposal
The appliance must be disposed of in accordance with the ad-
ministrative regulations of the respective country in which it is
used. National regulations and laws (in Germany, for example,
the End-of-Life Vehicle Regulation) must be observed.
Technical data
determined in accordance with EN 15033 or Truma test
conditions
Manufacturer
Truma Gerätetechnik GmbH & Co. KG
Postfach 1252
85637 Putzbrunn (Munich)
Germany
Protection class
IP21
Water capacity
10 litres
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Gas type
Liquid gas (propane / butane)
Operating pressure
30 mbar
Nominal heat load
1,6 A
Q
= 1.5 kW (H
); 120 g/h; C
n
i
Heating time from approx. 15 °C to approx. 70 °C
Gas mode: approx. 31 min.
Power supply
12 V
Power consumption at 12 V
Ignition:
0.25 A
Heating:
0.21 A
Standby:
0.06 A
Standby – gas consumption
approx. 70 W
Weight without water
7.5 kg
Destination countries
AT, BE, BG, CH, CY, CZ, DE, DK, EE, ES, FI, FR, GB, GR, HR,
HU, IE, IS, IT, LI, LT, LU, LV, MT, NL, NO, PL, PT, RO, SE, SI,
SK, TR
E1 10R-05 2604
Subject to technical changes.
Dimensions
All dimensions in mm.
Figure 4
; I
13
3B/P(30)
74
Gas connector
454
347
Water
connections
Electronics
Cowl
13