Danger of fire/explosion during refuelling.
The appliance must not be operated dur-
ing refuelling:
– the vehicle,
– the caravan's towing vehicle or
– other appliances.
Switch off the LP gas appliance at the control
panel. Shut off the gas supply to the LP gas
appliance. Make sure that the LP gas appli-
ance can definitely not be switched on under
any circumstances.
Repairs may only be carried out by an
expert!
Hot water can be dangerous and cause
burn injuries, particularly for toddlers,
children, older or infirm persons. Check the
water temperature every time before shower-
ing or bathing.
This appliance may be used by children
from 8 years old and by persons with
reduced physical, sensory or mental capabil-
ities or with a lack of experience only if they
are supervised or have been instructed in the
safe use of the appliance and understand the
resulting risks.
Children must not play with the
appliance.
In order to prevent any hazards caused
by unintentional resetting of the over-
temperature sensor, the appliance must not be
supplied with power via an external switching
device such as a time switch, or connected to
a power circuit that is regularly switched on
and off by a device.
The operating pressure of the gas sup-
ply (30 mbar) must be the same as the
operating pressure of the appliance (see type
plate).
10
The appliance, the gas system and the
exhaust duct for the combustion prod-
ucts must be inspected by a recognised expert
in accordance with the national regulations
(e.g. DVGW Worksheet G 607 in Germany) or,
if there are no such regulations, at least every
two years.
– A recognised specialist must carry out a leak
test after changes have been made to the
liquid gas system.
– The vehicle owner is responsible for having
the check carried out.
Any unusual burner noise or flame blow-
off suggests a fault in the gas pressure
regulation system, and makes it necessary to
check the gas pressure regulation system.
Never use objects (e.g. spray cans, can-
dles) or flammable materials, liquids,
gaseous substances or vapours in the vicinity
of the appliance, in the installation compart-
ment or in the appliance itself.
It is prohibited to use products contain-
ing chlorine on and inside the appliance.
Only gas pressure regulating systems
that comply with EN 16129 (in vehicles)
with a fixed output pressure of 30 mbar may
be used for the gas systems. The flow rate
of the gas pressure regulation system must
at least match the maximum consumption
of all the appliances installed by the system
manufacturer.