Switching on 230 V Electric Operation

(B 10 EL, B 14 EL only)
Switch the boiler on at the control panel (h). The indicator
lamp indicates that the device is in operation.
230 V ~
g = Rocker switch, "Off"
h = Rocker switch, "On (Electrical operation)"
When using the vehicle switches: refer to operating instructions
of the vehicle manufacturer.
The water temperature cannot be selected, automatic
temperature limitation at approx. 70 °C. For a faster
heating up period the appliance can be simultaneously oper-
ated with gas and electrical power.
The electrical heating element is equipped with an over-
temperature sensor. In the event of a fault, switch off at
the control panel, wait 10 minutes, then switch on again.

Maintenance

Always use original Truma parts for maintenance and
repair work!
We recommend the Truma system care set for cleaning,
disinfecting and looking after the boiler. Other products – in
particular products containing chlorine – are unsuitable.
To avoid infestation by micro-organisms, the boiler must be
heated to 70 °C at regular intervals.
B 10 EL, B 14 EL only
The device must be descaled on a regular basis (at least twice
a year).

Fuses

The fuse for the device is located on the electronic control unit.
1,6 A
The fine-wire fuse must only be replaced by a fuse of the
same design. 1.6 A (slow-acting), EN 60127-2-3.
If there is a defect in the electronics return the control p.c.b.
well padded. If you fail to pack it correctly the guarantee shall
no longer be valid.
Only use original Truma water heater control p.c.b.'s as
spare parts!

Disposal

The device must be disposed of in line with the administra-
tive regulations of the respective land in which it is used.
National regulations and laws (in Germany, for example,
the Altfahrzeug-Verordnung [old vehicle directive]) must be
observed.
Boiler EL
g
h

Technical data

determined in accordance with EN 15033 or Truma test
conditions
Type of gas
Liquid gas (propane / butane)
Operating pressure
30 mbar (see type plate)
Water contents
10 or 14 litres
Heating time up to approx. 70 °C
(10 litres)
Gas operation:
Electric operation:
Gas and electric operation: approx. 25 min.*
Heating time up to approx. 70 °C
(14 litres)
Gas operation:
Electric operation:
Gas and electric operation: approx. 38 min.*
Pump pressure
max. 2.8 bar
System pressure
max. 4.5 bar
Rated thermal output
1500 W
Gas consumption
120 g/h
Current input at 12 V
Ignition:
0.17 A
Heating up: 0.08 A
Stand-by:
0.04 A
Current input at 230 V*
850 W (3.7 A)
* B 10 EL, B 14 EL only
Weight (without water contents)
B 10 (EL) 6.7 kg
B 14 (EL) 7.3 kg

Dimensions

All dimensions in mm.
The right to effect technical modifications is reserved!
approx. 31 min.
approx. 45 min.*
approx. 50 min.
approx. 72 min.*
11