ENGLISH
OPERATING INSTRUCTIONS
The PUMA can be linked together as master/slave with 2 or 4 units and run the built in program chase
sequences by sound activation. When sound stops, all the lights will shut down (blackout) immediately and
the bulbs will turn off 15 seconds later. Please refer to the unit dipswitch-setting table for the
dipswitchsettings to achieve master/slave linking.
In master/slave mode, the dipswitch 10 on the master unit must be in the position " on ".
2-Channels dip switches setting
Master
Slave 1
Connect the optional CA-8 controller for more control:
The CA-8 controller can only be used in standalone or master/slave mode. Connect the controller to the CA-
8 input of the first unit (master). Now you can control all the connected units:
Stand by
Blackout the unit
Hold on for gobo strobe effect
Function
Fast mode: Sound activated
Mode
(LED off )
Controlled by universal DMX-controller:
Connect all units together. (don't
forget to address all units properly!)
Connect all units to the mains and
turn on the DMX controller.
Since each unit has its own DMX-
address,
you
can
control
them
individually. Remember that each unit
uses 4 DMX-channels as shown in the
DMX chart below:
JB SYSTEMS
®
OPERATION MANUAL
4-Channels dip switches setting
Master
Slave 1
Slave 2
Slave 3
Press shortly for gobo change
Slow mode: Not sound activated
(LED on)
5/30
ENGLISH
MAINTENANCE
Make sure the area below the installation place is free from unwanted persons during servicing.
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit's optics.
Clean with a soft cloth using normal glass cleaning products.
Always dry the parts carefully.
Clean the external optics at least once every 30 days.
Clean the internal optics at least every 90 days.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!
SPECIFICATIONS
Mains Input:
Fuse:
Sound Control:
DMX connections:
Lamp:
Size:
Weight:
You can download the latest version of this user manual on our website: www.beglec.com
PUMA
JB SYSTEMS
AC 230V, 50Hz
20mm Glass 5A Fast Blow(20mm glass)
Internal microphone
3pin XLR male / female
ELC 250W/24V
263 x 314 x 202 mm
7.7 kg
Every information is subject to change without prior notice