ATEX Installation Drawings, UK, FR, DE, DK - 6334B
LERBAKKEN 10, 8410 RØNDE DENMARK.
6331
For safe installation of 6331Bxx or 6334Bxx the following must be observed. The module shall only
be Installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
ATEX Certificate
Marking
Standards
Hazardous area
Zone 0, 1, 2
T5: -40 ≤ Ta ≤ 60ºC
T6: -40 ≤ Ta ≤ 40ºC
Terminal:
41,42,43,44
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Terminal:
51,52,53,54
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Installation notes:
The sensor circuit is not infallibly galvanically isolated from the input circuit. However, the
galvanic isolation between the circuits is capable of withstanding a test voltage of 500Vac
during 1 minute.
Revision date:
2009-09-29
All manuals and user guides at all-guides.com
ATEX Installation drawing
KEMA 06ATEX 0115
II 1 G Ex ia IIC T6..T5
EN 60079-0 : 2006, EN 60079-11 : 2007, EN 60079-26 : 2007
44
+
43
13
-
42
11
41
CH1
54
+
53
23
-
52
21
51
CH2
6331 / 6334
Version Revision
V1R0
6334V105
6331QA01
WWW.PRELECTRONICS.COM
Non Hazardous Area
Barrier
Terminal:
11,13 and
21,23
Ui: 30 VDC
Ii: 120 mA
Pi: 0.84 W
Li: 10 μH
Ci: 1.0 nF
Barrier
Page:
1/1