Displays
Programmable displays with a wide
selection of inputs and outputs for display of temperature,
volume and weight, etc. Feature linearisation, scaling, and
difference measurement functions for programming via
PReset software.
Ex interfaces
Interfaces for analogue and digital signals
®
as well as HART
signals between sensors / I/P converters /
frequency signals and control systems in Ex zone 0, 1 & 2
and for some modules in zone 20, 21 & 22.
Isolation
Galvanic isolators for analogue and digital
signals as well as HART
®
signals. A wide product range
with both loop-powered and universal isolators featuring
linearisation, inversion, and scaling of output signals.
Temperature
A wide selection of transmitters for DIN
form B mounting and DIN rail modules with analogue
and digital bus communication ranging from application-
specifi c to universal transmitters.
Universal
PC or front programmable modules with
universal options for input, output and supply. This range
offers a number of advanced features such as process
calibration, linearisation and auto-diagnostics.
All manuals and user guides at all-guides.com
6 3 3 3
2 - W i r e P r o g r a m m a b l e
T r a n s m i t t e r
N o . 6 3 3 3 V 1 0 2 - I N ( 0 9 2 3 )
F r o m s e r . n o . 0 0 0 0 3 4 0 0 1
S I G N A L S T H E B E S T
Side 1
DK
Page 13
UK
Page 25
FR
Seite 37
DE

Publicité

loading

Sommaire des Matières pour PR electronics PRetrans 6333

  • Page 1 All manuals and user guides at all-guides.com Displays Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearisation, scaling, and difference measurement functions for programming via PReset software. Ex interfaces Interfaces for analogue and digital signals ®...
  • Page 2 All manuals and user guides at all-guides.com 2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetrans 6333 Indholdsfortegnelse Sikkerhedsinstruktion ............EF-overensstemmelseserklæring ........Anvendelse ................. Teknisk karakteristik ............Montage / installation ............Applikationer ..............Bestillingsskema..............Elektriske specifikationer ........... Tilslutninger ................ Blokdiagram ............... 10 Programmering ..............11...
  • Page 3 Navn: 2-tråds programmerbar transmitter Reparation: er i overensstemmelse med følgende direktiver og standarder: Reparation af modulet må kun foretages af PR electronics A/S. EMC-direktivet 2004/108/EF og senere tilføjelser EN 61326-1 : 2006 For specifikation af det acceptable EMC-niveau henvises til modulets elektriske specifikationer.
  • Page 4 All manuals and user guides at all-guides.com 2-TRÅDS PROGRAMMERBAR TRANSMITTER PRetrans 6333 2-trådsinstallation i kontrolrum RTD til 4...20 mA • Indgang for RTD eller Ohm • Høj målenøjagtighed • 3-leder tilslutning • Programmerbar følerfejlsværdi • 1- eller 2-kanals version Anvendelse: 2-trådsinstallation...
  • Page 5 All manuals and user guides at all-guides.com Basisværdier Bestillingsskema: 6333 Basis- Temperatur- Indgangstype nøjagtighed koefficient ≤ ±0,3°C ≤ ±0,01°C / °C ≤ ±0,2 Ω ≤ ±20 mΩ / °C Lin.R Galvanisk Type Version Kanaler isolation ≤ EMC-immunitetspåvirkning ......... ±0,5% af span Standard Ingen Enkelt...
  • Page 6 All manuals and user guides at all-guides.com Følerfejlsdetektering: Programmerbar ........... 3,5...23 mA NAMUR NE43 Upscale ....... 23 mA NAMUR NE43 Downscale ......3,5 mA EEx- / I.S.-godkendelse: 26959 ........ II 1 G DEMKO ATEX1 EEx ia IIC T1...T6 Max. omgivelsestemp. for T1...T6 ....60°C Anvendes i zone ..........
  • Page 7 All manuals and user guides at all-guides.com Programmering: • Loop Link er et batteridrevet kommunikationsinterface, der er nødvendigt for programmering af PRetrans 6333. • Ved programmering henvises til tegningen nedenfor og hjælpefunktionen i PReset programmet. • Ved kommunikation med ikke-installerede moduler må stikkene 11, 12, 13 (kanal 1) og 21, 22, 23 (kanal 2) af monteres, så...
  • Page 8 All manuals and user guides at all-guides.com 2-WIRE PROGRAMMABLE TRANSMITTER PRetrans 6333 Contents Safety instructions .............. 14 EC Declaration of Conformity ..........15 Application ................. 16 Technical characteristics ............ 16 Mounting / installation ............16 Applications ................ 17 Order .................. 18 Electrical specifications ............
  • Page 9 Name: 2-wire programmable transmitter Repair: is in conformity with the following directives and standards: Repair of the module must be done by PR electronics A/S only. The EMC Directive 2004/108/EC and later amendments EN 61326-1 : 2006 For specification of the acceptable EMC performance level, refer to the electrical specifications for the module.
  • Page 10 All manuals and user guides at all-guides.com 2-WIRE PROGRAMMABLE TRANSMITTER PRetrans 6333 2-wire installation RTD to 4...20 mA in control room • RTD or Ohm input • High measurement accuracy • 3-wire connection • Programmable sensor error value • 1- or 2-channel version...
  • Page 11 All manuals and user guides at all-guides.com Basic values Order: 6333 Basic Temperature Input type accuracy coefficient ≤ ±0.3°C ≤ ±0.01°C / °C ≤ ±0.2 Ω ≤ ±20 mΩ / °C Lin. R Galvanic Type Version Channels isolation ≤ EMC immunity influence ........±0.5% of span Standard None...
  • Page 12 All manuals and user guides at all-guides.com Sensor error detection : Programmable ..........3.5...23 mA NAMUR NE43 Upscale ....... 23 mA NAMUR NE43 Downscale ......3.5 mA EEx / I.S. approvals: DEMKO 99ATEX126959 ......II 1 G EEx ia IIC T1...T6 Max.
  • Page 13 All manuals and user guides at all-guides.com Programming: • Loop Link is a battery-powered communications interface that is needed for programming PRetrans 6333. • For programming please refer to the drawing below and the help functions in PReset. • When communicating with non-installed modules, connectors 11, 12, 13 (channel 1) and 21, 22, 23 (channel 2) can be dismantled to connect the terminals of the communications interface to the pins.
  • Page 14 All manuals and user guides at all-guides.com TRANSMETTEUR 2-FILS PROGRAMMABLE (Pt100) PRetrans 6333 Sommaire Consigne de sécurité ............26 Déclaration de conformité CE ..........27 Application ................. 28 Caractéristiques techniques ..........28 Montage / installation ............28 Applications ................ 29 Référence ................
  • Page 15 Nom : Transmetteur 2-fils programmable (Pt100) Réparation : correspond aux directives et normes suivantes : Seule PR electronics SARL est autorisée à réparer le module. La directive CEM (EMC) 2004/108/CE et les modifications subséquentes EN 61326-1 : 2006 Pour une spécification du niveau de rendement acceptable CEM (EMC) renvoyer aux spécifications électriques du module.
  • Page 16 TRANSMETTEUR 2-FILS PROGRAMMABLE (Pt100) Installation 2-fils RTD en 4...20 mA en salle de contrôle PRetrans 6333 • Entrée RTD ou résistance • Grande précision de mesure • Connexion aux sondes à 3 fils • Sécurité programmable • Version 1- ou 2-voies Résistance...
  • Page 17 All manuals and user guides at all-guides.com Valeurs de base Référence : 6333 Type Précision Coefficient d’entrée de base de température ≤ ±0,3°C ≤ ±0,01°C / °C ≤ ±0,2 Ω ≤ ±20 mΩ / °C R. lin. Isolation Type Version Voies galvanique ≤...
  • Page 18 All manuals and user guides at all-guides.com Détection de rupture de sonde : Programmable ..........3,5...23 mA NAMUR NE43 Haut d’échelle ..... 23 mA NAMUR NE43 Bas d’échelle ....... 3,5 mA Approbation EEx / S.I : 126959........ II 1 G DEMKO ATEX EEx ia IIC T1...T6...
  • Page 19 All manuals and user guides at all-guides.com Programmation : • Loop Link est un kit de programmation permettant de programmer le PRetrans 6333. • Pour le raccordement du Loop Link, veuillez vous reporter au schéma ci- dessous et à l’aide en ligne du logiciel PReset.
  • Page 20 All manuals and user guides at all-guides.com 2-DRAHT PROGRAMMIERBARER MESSUMFORMER PRetrans 6333 Inhaltsverzeichnis Sicherheitsanweisung ............38 EG-Konformitätserklärung..........39 Verwendung ................ 40 Technische Merkmale ............40 Montage / Installation ............40 Anwendungen ..............41 Bestellangaben ..............42 Elektrische Daten ............... 42 Anschlüsse .................
  • Page 21 Typ: 6333 Name: 2-Draht programmierbarer Messumformer Reparatur: die Konformität mit folgenden Richtlinien und Normen: Reparatur des Moduls muss nur von PR electronics A/S vorgenommen werden. Die EMV Richtlinien 2004/108/EG und nachfolgende Änderungen EN 61326-1 : 2006 Zur Spezifikation des zulässigen Erfüllungsgrades, siehe die Elektrische Daten des Moduls.
  • Page 22 All manuals and user guides at all-guides.com 2-DRAHT PROGRAMMIERBARER MESSUMFORMER PRetrans 6333 2-Draht-Installation im Kontrollraum • Eingang für WTH oder Ω WTH in 4...20 mA • Hohe Messgenauigkeit • 3-Leiter-Anschluss • Programmierbare Sensorfehlanzeige • 1- oder 2-kanalige Ausführung: Verwendung: 2-Draht-Installation im Kontrollraum •...
  • Page 23 All manuals and user guides at all-guides.com Grundwerte Bestellangaben: 6333 Grund- Temperatur- Eingangsart genauigkeit koeffizient ≤ ±0,3°C ≤ ±0,01°C / °C ≤ ±0,2 Ω ≤ ±20 mΩ / °C Lin.R Galvanische Version Kanäle Trennung ≤ EMV-Immunitätswirkung ........±0,5% d. Messsp. Standard Ingen Einkanalig...
  • Page 24 All manuals and user guides at all-guides.com Fühlerfehlererkennung: Programmierbar .......... 3,5...23 mA Namur NE43 - aufsteuernd ......23 mA Namur NE43 - zusteuernd ......3,5 mA EEx- / I.S.-Zulassung: DEMKO 99ATEX126959 ......II 1 G EEx ia IIC T1...T6 Max. Umgebungstemperatur. für T1...T6 ... 60°C Anwendungsbereich ........
  • Page 25 All manuals and user guides at all-guides.com Programmierung: • Loop Link ist eine batteriegespeiste Schnittstelle zur Programmierung des PRetrans 6333. • Bezüglich Programmierung verweisen wir auf die nachfolgende Zeichnung und die “Hilfe”-Funktion im PReset-Programm • Bei der Kommunikation mit Modulen, die nicht installiert sind, ist es not-...
  • Page 26 All manuals and user guides at all-guides.com Subsidiaries PR electronics A/S tilbyder et bredt program af analoge og digitale France signalbehandlingsmoduler til industriel automation. Programmet PR electronics Sarl Zac du Chêne, Activillage sales@prelectronics.fr består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, 4, allée des Sorbiers tel.