ATEX Installation Drawings, UK, FR, DE, DK - 6334A
LERBAKKEN 10, 8410 RØNDE DENMARK.
For safe installation of 6331A or the 6334A the following must be observed. The module shall only
be installed by qualified personnel who are familiar with the national and international laws,
directives and standards that apply to this area.
Year of manufacture can be taken from the first two digits in the serial number.
ATEX Certificate
Marking
Standards
T5: -40ºC to 60 ºC
T6: -40ºC to 40 ºC
Terminal:
41,42,43,44 /
51,52,53,54
Ex nA [nL]
Uo: 9.6 VDC
Io: 25 mA
Po: 60 mW
Lo: 33 mH
Co: 2.4 μF
Special conditions for safe use.
For use in a potentially explosive atmosphere of flammable gasses, vapours or mists, the
transmitter shall be mounted in an enclosure providing a degree of protection of at least IP54 in
accordance to EN60529.
Revision date:
2009-11-17
All manuals and user guides at all-guides.com
ATEX Installation drawing
KEMA 10ATEX 0005X
II 3 G Ex nA [nL] IIC T6..T5
II 3 G Ex nL IIC T6..T5
II 3 G Ex nA [ic] IIC T6..T5
II 3 G Ex ic IIC T6..T5
EN 60079-0 : 2006, EN 60079-11 : 2007, EN 60079-15 : 2005
44
43
42
41
CH1
54
53
52
51
CH2
6331 / 6334
Version Revision
V1R0
6334V105
WWW.PRELECTRONICS.COM
Hazardous Area Zone 2
+
13
Terminal:
-
11-13 / 21-23
11
Ex nA
U ≤ 35 VDC
I = 4 - 20 mA
Ex nL or Ex ic
+
23
Ui = 35 VDC
-
21
Li = 10 μH
Ci = 1.0 nF
6331QA02
Page:
1/1
49