SERVICING YOUR
HUMIDIFIER
CLE ANING THE GE AR
DO NOT submerge the gear in water. To clean any buildup of calcium or lime from the
gear "teeth," brush with a soft bristled brush. The gear teeth should be pointed toward the
floor while brushing, otherwise deposits will fall into the gear and cause it to malfunction.
REMOVAL OF THE GE AR AND COUPLING
1. Switch the unit off.
2. Unplug the power cord from the outlet.
3. Remove the motor from the upper
housing.
4. Remove the coupling from the gear by
pushing the coupling down toward the
fan and away from the gear
5. Pivot turn the gear 90 degrees, so that
it is laying on its side.
Fig 4. ... Push the coupling down ...
Fig 5. ... turn the gear 90 degrees ...
6. Gently pull one of the two motor as-
sembly arms approximately 1/8 of an
inch away from the gear and remove
the gear from the motor assembly.
7. Remove the locking ring from the cen-
ter shaft of the fan by prying it up using
a small screwdriver.
Fig 6. ... gently pull one of the motor assembly
arm 1/8 inch ...