CLEANING & MAINTENANCE
Attention! Ensure that the device is switched off during any troubleshooting and
!
the power supply is disconnected from the outlet!
Display
8
WATER
9
SERVICE
Any remaining liquid in the water tray and on the disk stack (white, green-yellow or
brown deposits or discolorations) do NOT impair the function of the device.
Troubleshooting
Remove upper housing. Fill lower housing with tap water up to
the WATERLINE marking. Place upper housing on lower housing
and put device in operation again.
As soon as there is not enough water in the lower housing,
i
the device is switched off automatically and the WATER
display appears. In the HUMIDITY display 1, two lines will
flash and the humidity in the room is not shown.
To humidify the room air continuously, we recommend
refilling the water in a timely manner.
Remove upper housing. Drain residual water from lower housing.
Rinse lower housing and disk stack. Fill lower housing with tap
water up to the WATERLINE marking maximum and add the Venta
Water Treatment Additive (WTA) (for dosage see scale on rear of
bottle). Re-assemble the device. Touch SERVICE display 9 in the
display and hold it for 3-5 seconds until it goes off.
For flawlessly hygienic continuous operation, the SERVICE
i
display indicates a reminder every 14 days that it is time to
clean your humidifier.
You may clean the humidifier even if the SERVICE message
is not shown. Afterwards, simply touch SERVICE display
and hold for 3-5 seconds. The next reminder will now be
shown again in 14 days with the SERVICE message