Burner injector:
Exchange of injector for the burners
1. Turn all control knobs to off positions
on the control panel.
2. Shut off the gas supply.
3. Remove the pan supports, the cap and
head of the hob burners.
4. Remove the gas injectors by turning
counter clockwise. (spanner 7)
5. If your product has a wok combustor
with a side-entry injector, remove the in-
jector with a number 7 spanner.
On some hob burners, the injector
is covered with a metal piece. This
metal cover must be removed for
injector replacement.
6. Install the new gas injectors. (Tightening
torque 4 Nm)
7. Check all connections in order to make
sure that they are installed safely and
securely.
New injectors have their position
marked on their packing or injector
table on can be referred to.
8. You must check for leakage injectors
after connection.
Unless there is an abnormal condi-
tion, do not attempt to remove the
gas burner taps. You must call an
Authorised service agent or techni-
cian with licence if it is necessary
to change the taps.
Reduced gas flow rate setting for hob taps
1. Ignite the burner that is to be adjusted
and turn the knob to the reduced posi-
tion.
2. Remove the knob from the gas tap.
3. Use an appropriately sized screwdriver
to adjust the flow rate adjustment
screw.
4. For LPG (Butane - Propane) turn the
screw clockwise. For the natural gas,
you should turn the screw counter-
clockwise once.
ð The normal length of a straight
flame in the reduced position
should be 6-7 mm.
5. If the flame is higher than the desired
position, turn the screw clockwise. If it
is smaller turn anticlockwise.
6. For the last control, bring the burner
both to high-flame and reduced posi-
tions and check whether the flame is on
or off.
7. Depending on the type of gas tap used
in your appliance the adjustment screw
position may vary.
Flow rate adjustment screw
1
EN / 30
EN