Télécharger Imprimer la page

Hitachi airPoint Room H700 Manuel D'installation Et De Fonctionnement page 33

Publicité

2. Set ECO mode with Auto-Off.
This function is available with indoor unit models equipped with motion sensor. Adjusts the set
temperature when "no people are in the room" then automatically turns off after a set time for energy
saving.
Step1.
Press " " or " " to select "ECO mode with Auto-
Off" on the "Functions for ECO mode" screen and
press "OK".
Step2.
Select "Yes" and press "OK" to enable ECO mode
with Auto-Off.
NOTE:
Please be aware that the air conditioner may shut off unexpectedly in the following scenarios.
Therefore, recommend not to enable the "ECO mode with Auto-Off" setting in the situations as
below:
When a person is present in an area where the human sensor cannot detect their presence.
When there is a sleeping person, especially an infant or young child.
When only a pet is present.
The unit finds absence.
Present
Normal operation
A16382H32B
After enabling this mode, "
displayed on the home screen.
The sensor starts to detect the presence of
people in the room.
If no people are detected for 20 minutes,
the set temperature automatically adjusts
for energy savings. In the absence of any
occupants for 60 minutes, the unit will go to
Standby mode.
The unit reverts to its regular operation when
the sensor detects human movement.
ECO mode with Auto-Off Control Diagram
Approx. 60 min.
Approx.
10 min.
Set temperature shi operation
Follows "Standard ECO mode"
[Diagram representation for illustrative purpose only]
6. Function Menu Screen Display
" and "
" are
Auto-Off
Absent
Functions for ECO mode
Standard ECO mode
ECO mode with Auto-Off
PowerSafe mode
OK
Select
Functions for ECO mode
Standard ECO Mode
ECO Mode with Auto-OFF
Enable ECO mode with Auto-Off?
PowerSafe mode
Yes
Cancel
OK
Select
27
. 0
27
.
0
Temp
Cool
Fan Speed
Louver
The operation stops
Back
Back
My Mode
29

Publicité

loading

Ce manuel est également adapté pour:

Spx-urfg1