• Repairs must only be carried out by Customer Services or au-
thorised retailers. Before making a complaint, first check the
batteries and replace them if necessary.
• The device must not be disposed of with household waste.
Dispose of the device at a suitable local collection or
recycling point in your country. Dispose of the device in
accordance with EC Directive – WEEE (Waste Electrical
and Electronic Equipment). Please contact the local authori-
ties responsible for waste disposal if you have any questions
regarding disposal.
Disposal of the batteries
• Used, completely discharged batteries must not be disposed
of with household waste. Dispose of the batteries in specially
designated collection boxes, at recycling points or at electron-
ics retailers. You are legally required to dispose of the batteries
correctly.
• The codes below are printed on batteries containing harmful
substances:
- Pb = battery contains lead
- Cd = battery contains cadmium
- Hg = battery contains mercury
11. TECHNICAL SPECIFICATIONS
Type
BM 28
Measurement
Oscillometric, non-invasive blood pressure
method
measurement on the upper arm
Measurement range Cu pressure 0-300 mmHg,
systolic 50-280 mmHg,
diastolic 30-200 mmHg,
pulse 40-199 beats/minute
Display accuracy
Systolic ± 3 mmHg, diastolic ± 3 mmHg,
pulse ± 5% of the value shown
Measurement
Max. permissible standard deviation
uncertainty
according to clinical testing:
systolic 8 mmHg / diastolic 8 mmHg
Memory
4 x 30 memory spaces
Dimensions
L 134 mm x W 103 mm x H 60 mm
Weight
Approximately 367 g (without batteries,
with cu )
Cu size
22 to 42 cm
Permissible operat-
+10 °C to +40 °C, <90% relative humidity,
ing conditions
800-1050 hPa ambient pressure
Permissible storage
-20 °C to +55 °C, <90% relative humidity
conditions
(non-condensing)
Power supply
4 x 1.5 V
Battery life
For approx. 300 measurements, depend-
ing on levels of blood pressure and pump
pressure
Classification
Internal supply, IP21, no AP or APG, con-
tinuous operation, application part type BF
Product life cycle to
Information on the life cycle of the product
be expected
can be found at beurer.com
The batch number is located on the device or in the battery com-
partment.
We reserve the right to make technical changes to improve and
develop the product.
• This device conforms with the European standard
EN 60601-1-2 (in accordance with CISPR-11, IEC 61000-3-2,
IEC 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4,
IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-7, IEC 61000-4-8,
32
AA batteries