Connecting the refrigerator
Item in
fig. l, page 13
17
18
19
20
21
22
23
24
25
DC power
!
WARNING! Fire hazard
• The supply line to the heating element must be protected with a
15 A fuse.
• The supply line to the electronics must be protected with a 2 A fuse.
A
NOTICE!
The respective positive and negative supply lines of the DC connections
for electronics (fig. l 16, page 13) and heating element (fig. l 17,
page 13) may not be joined with one another and carried on a single
wire. This can cause electrical interference or damage to electrical com-
ponents.
Please note the following cable sizes (fig. m, page 15):
• Cross section for connections to the heating element: min. 6 mm²
To guarantee a proper cooling performance ensure that the voltage loss is
<0.8 Vg from the power supply to the refrigerator connection terminal.
• Connections electronics and heating element: 0.75 mm
• Connections electronics: 0.75 mm
• Connections D+ and S+: 0.75 mm
30
Description
DC supply cable heating element
CI-Bus connection
AC power supply
Heating element AC
Ground
AC protection Earth
Ignition electrode
Power module
Display module
2
2
RM10.5, RMS10.5
2