Installing the refrigerator
Refrigerator
Recess
Height (H)
Width (W)
Depth (D)
• The refrigerator must be installed with a minimum distance of 5 mm from the floor
to ensure that the door can be opened properly (fig. 3, page 4).
– The refrigerator must rest completely on the floor of the furniture up to the
front edge of the door (B).
– Avoid placing the refrigerator directly on the floor.
– Ensure that no carpets interfere with the free movement of the door.
• The outer wall must be fitted with an air inlet vent (fig. 4 1, page 5) and an outlet
vent (fig. 4 2, page 5) with ventilation grilles so that the heat generated can be
easily released to the outside:
– Air inlet vent: Fit ventilation grille as flush as possible with the base of the
installation niche.
– Outlet vent: fit as far above the refrigerator as possible.
– The distance between the air inlet and outlet vents must be at least 750 mm
for RM10.5 and 534 mm for RMS10.5 (fig. 5, page 5).
• Fit a heat conduction plate (fig. 5 1, page 5) above the refrigerator so that the
heat does not accumulate in the vehicle.
• The distance between the refrigerator and the rear wall must be at least 15 mm
but no more than 25 mm.
• A distance of more than 25 mm between the refrigerator and rear wall leads to
poor performance and increases the power consumption of the refrigerator.
Reduce the space behind the refrigerator to create adequate air inlet and outlet
ventilation (fig. 6, page 6). Use a ventilation plate, for example, to do this.
22
RM10.5
RMS10.5
(S)(G)(T)(P)
(S)(G)(T)(P)
Overall dimension in mm
Dimension in mm
829
525.5
525.5
563
RM10.5, RMS10.5
RMS10.5X
(S)(G)(T)(P)
829
829
525.5
563
618
EN

Publicité