will read:
GRINDING.
XXX
Using the ▲ ▼ keys, it is possible to select
XXX as:
• NOT ACTIVE (pouring times will not be
shown).
• ROW 1 (pouring times will be shown in row 1.
• ROW 2 (pouring times will be shown in row 2).
• Press ENTER to confirm and pass to the
next step.
• Press RESET to return to the previous page
without confirming.
If the delivery time display is on when a
delivery is started - unless with the
Continuous function - the bottom line of the
display will show the delivery time (or times
if more than one unit is delivering).
Each group has an area of the bottom line:
the area on the left is for unit 1; the area
alongside it is for unit 2 and so on, until the
area on the far right, which is for unit 4.
The different areas are separated by vertical
bars; if a group is not delivering, the area is
empty.
Here below is an example: unit 1 is deliver-
ing (it has just started and 0 seconds have
passed); unit 2 has been delivering for 12
seconds and unit 4 is delivering (it has been
delivering for 21 seconds).
Area reserved to the
Area reserved to the
delivery time of unit 2
delivery time of unit 3
Thursday
12:00
0 I 12 I
I 21
Area reserved to the
Area reserved to the
delivery time of unit 1
delivery time of unit 4
SETTING THE SET POINT PRESS
The SETPOINT PRESS: allows to chose the
pressure/ temperature in the working status.
SETPOINT PRESS
When the ENTER key is pressed, the display
will read:
SETPOINT PRESS
XX.XX BAR
Press ▲ ▼ to adjust the work-press/temp
point.
• Press ENTER to confirm and pass to the
next step.
• Press RESET to return to the previous page
without confirming.
PRESSURE - TEMPERATURE TABLE
Bar
°C
0,50
110,5
0,55
111,5
0,60
112,5
0,65
113,5
0,70
114
0,75
115
0,80
115,5
0,85
116,5
Bar
°C
0,90
117,5
0,95
118
1,00
119
1,05
119,5
1,10
120,5
1,15
121
1,20
122
1,25
1,30
1,35
1,40
1,45
1,50
1,55
1,60
HISTORICAL ALARM VISUALISATION:
• The display will read:
FAULTS HISTORY
• By pressing the ENTER,key, the display will
read:
ERROR 01
• Pressing the ▼key, allows you to scroll
down the ten previous alarms saved in the
memory. After the tenth alarm, by pressing
the ▼ key again you can go on to the next
°F
page.
230,9
232,7
234,5
236,3
237,2
239
239,9
241,7
°F
243,5
244,4
246,2
247,1
248,9
249,8
251,6
112,5
252,5
123
253,4
124
255,2
124,5
256,1
125
257
126
258,8
126,5
127