ery, has been completed the selected unit
key will begin to flash on and off again
and the display will read:
RINSE
• Eliminate any residues of PULICAFF from the
blind filter and press
the rinsing cycle start-
ing up key of the unit or units where the cleaning
cycle has been effected. The letter R will remain
on the display like the key
. Once the rins-
ing cycle of the selected unit or units has been
completed, the display will read:
MACHINE READY
If ACTIVE has been selected in the function
"DELIVER WHILE WASHING" (see func-
tion), after the groups to be cleaned have
been selected, pressing the ENTER key will
quite the washing mode to use the other,
non-selected units to deliver coffee. When
the washing mode is closed to make the
units not being washed available to deliver
coffee, the washing cycle will be shown in
the top or bottom line of the screen, accord-
ing to the choice made in the "DELIVERING
TIME" menu. If the delivering times are
deactivated, the washing process will be
displayed on the bottom line. It is not possi-
ble to open the setting menu and to switch
off the machine, either manually or automat-
ically, during an automatic washing cycle not
in the menu (therefore, with delivering ena-
bled).
PROGRAMMING DOSES:
• The display will read:
PROGRAM.DOSES
• Press ENTER and the display will read:
PROGRAM.DOSES
SELECT
All the programmable keys will start to flash
on and off.
Coffee:
• Press the coffee key you wish to program;
the dis-play will read:
VOLUME C.C:
Followed by the dose amount already set by
the manufacturers.
• Vary the dose, by pressing the buttons ▲ ▼.
• By pressing the coffee key you want to pro-
gram, delivery will be started up (in the
meantime all the other keys will turn off).
• Once you have the required dose, press the
continuous coffee key
to stop pouring..
• The display will show the new dose amount
which can still be changed by means of the
keys ▲ ▼.
• Press the ENTER key to confirm the pro-
grammed dose.
• Press the RESET key to cancel program-
ming.
• The programmed coffee key will switch off.
Hot Water:
• Press the
button and make sure that it
lights up. The display will read:
PROGRAM. DOSES
SECONDS X.X
The value X.X is the default setting.
Press the ▲ ▼ keys to vary the hot water
delivery time.
• If a new sampling is desired press the
button again.
Delivery starts. When the desired dose has
been reached press the button again
•The display will show the new dose value set
which can still be changed by pressing the▲
▼ keys.
• Press the ENTER key or go on to a further
selection to terminate the operation.
• Press the RESET key to cancel program-
ming.
The
button will turn off.
Timed steam:
•Press the
button and make sure it lights up.
In those models provided with a temperature
probe (optional) the control unit automatical-
ly recognizes the presence of the probe and
the display will read:
PROGRAM. DOSES
STEA. TEM.
°C
followed by the temperature set previously
by the manufacturer.
Press the ▲ ▼ keys to vary the tempera-
ture of the beverage you want to heat. When
the desired temperature has been reached,
the steam delivery will automatically stop.
.
.
51

Publicité

loading