A
• Turn the pump registration screw, turning it
clock-wise to INCREASE and counter clock
wise to DECREASE the pressure;
Advisable pressure:
9 bar
• The set pump pressure is displayed in the pres-
sure gauge, inside the machine (see Fig. 11);
At the end of the adjustment process, refit the
sheet metal guard on the relevant housing and
secure it in place with the two side screws. Refit
the drip tray and the work surface grid.
3.3
HOT WATER
ECONOMISER
ADJUSTMENT
NOTE: This operation can be carried out while
the machine is turned on.
All models
water mixer tap which adjusts the water temper-
Fig. 9
ature and optimises the system's performance.
To adjust the hot water economiser, turn the
registration knob.
• The hot water economiser is located inside
the machine;
• To access the economiser, remove the cup
warm-er section on the left by loosening the
two screws "D" as illustrated in the follow-
ing figure.
Fig. 10
• Turn the adjustment knob ANTICLOCKWISE
/ CLOCKWISE to INCREASE / REDUCE
the temperature of the hot water;
Fig. 11
• when the operation has been completed,
screw the protective panel back on.
3.4
The electronic control unit is equipped with a
lithium battery to provide the clock with an
approximately three-year autonomy period,
after which replacing the battery may prove
necessary.
re equipped with a hot
In case the machine has remained unutilised
for a long time, the clock can be blocked by
proceeding as follows:
• with the machine off the display will read:
• Press the ENTER key for 5 seconds; the
display will read:
D
The clock will start up again as soon as the
machine is plugged in once more.
Fig. 12
Replacement of the lithium battery must be
carried out EXCLUSIVELY by Qualified
Technician.
Simonelli Group cannot be held liable for
any damage to people or things due to non
observance of the safety prescriptions
described in this booklet.
Fig. 13
CLOCK BATTERY
REPLACEMENT
OFF
STOP CLOCK
WARNING
45