6.4.6
External teach-in
6.4.7
Channel switching
7
Disposal
8
Maintenance
8015556/1PJO/2024-10-07 | SICK
Subject to change without notice
The switching threshold display flashes and
the display shows the basic display.
The teach-in input (ET) must be activated for > 200 ms to perform a teach-in process
(ET at > 10 V ... < UV for PNP devices; ET at 0 V for NPN devices).
Pressing the
pushbutton switches between channel 1 (ch1) and channel 2 (ch2).
Figure 9: Channel switching
The product must be disposed of in line with applicable country-specific regulations.
When disposing of them, you should try to recycle them (especially the precious met‐
als).
NOTE
Disposal of batteries, electric and electronic devices
According to international directives, batteries, accumulators and electrical or
electronic devices must not be disposed of in general waste.
The owner is obliged by law to return this devices at the end of their life to the
respective public collection points.
WEEE:
This symbol on the product, its packaging or in the document
indicates that a product is subject to the specified regulations.
This SICK sensor is maintenance-free.
We do, however, recommend that the following activities are undertaken regularly:
Clean the optical interfaces and housing
Check the fittings and plug connectors
Cleaning
NOTICE
Equipment damage due to improper cleaning.
Improper cleaning may result in equipment damage.
Only use recommended cleaning agents and tools.
Never use sharp objects for cleaning.
OPERATING INSTRUCTIONS
O P E R A T I N G I N S T R U C T I O N S | WLL180T-x632, WLL180T-x634