Table 19: ASC setting
A S c
o F F
TOP
4.10 Setting the strength of the sender LED
Table 20: Strength of the sender LED
TOP
4.11 Lock level
OPERATING INSTRUCTIONS
Setting ASC
SAM Circuit (ASC = Automatic Sensitivity Control) Thresh‐
old value is automatically reset while the sensor
continuously checks the received light. A sudden
change in the amount of light, such as cleaning the
lens, resets the threshold value.
Select
and adjust
. The display reverts to the
ASC setting mode top menu.
Switch off ASC.
o F F
Automatically adjust the threshold
o n
value to the environment.
NOTE
Threshold setting preferably after
cleaning.
1)
Factory setting
Illuminance can be selected in three levels.
Select
and adjust
. The display reverts to the
Illumination top menu.
Table 21: Input
Standard setting
Medium-strength setting
Low-strength setting
1)
Factory setting
NOTE
Tip: Avoid saturation of the received light.
O P E R A T I N G I N S T R U C T I O N S | WLL180T-x632, WLL180T-x634
1)
1)
43