OPERATING INSTRUCTIONS
en
5.2
Notes on connection
5.3
Connection diagram
36
O P E R A T I N G I N S T R U C T I O N S | WLL180T-x632, WLL180T-x634
When using extension cables with open ends, ensure that bare wire ends do not
■
come into contact with each other (risk of short-circuit when supply voltage is
switched on!). Wires must be properly insulated from each other.
Wire cross-sections in the supply cable from the user's power system must be
■
selected in accordance with the applicable standards.
NOTE
Layout of data cables
Use shielded data cables with twisted-pair wires.
■
Implement proper and complete shielding concept.
■
To avoid interference, e.g., from switching power supplies, motors, clocked regula‐
■
tors and contactors, always use cables and layouts that are suitable for EMC.
Do not lay cables over long distances in parallel with voltage supply cables and
■
motor cables in cable ducts.
The IP enclosure rating for the device is only achieved under the following conditions:
The cables plugged into the connections are screwed tight.
■
If these instructions are not complied with, the IP enclosure rating for the device is not
guaranteed!
Only apply voltage and switch on the voltage supply once all electrical connections have
been established.
DC: 12 ... 24 V DC,
see "Technical data", page 50
NPN
5
6
PNP
6
5
Connection dia‐
3
gram
4
1
1
1
2
4
3
2
4
2
3
6
4
7
8
5
3
6
1
1
7
6
2
3
8
3
4
2
7
8
4
1
1
2
3
2
4
BN: 12 ... 24 V DC (base unit
only)
Load
BK: Digital output Q
1
GR: Digital output Q
2
Circuit
Suppressor elements
WH: External input (cabled
device only)
BU: 0 V (base unit only)
12 ... 24 V DC
Digital output Q
2
0 V
digital output Q
1
8015556/1PJO/2024-10-07 | SICK
Subject to change without notice