OPERATING INSTRUCTIONS
en
38
O P E R A T I N G I N S T R U C T I O N S | WLL180T-x632, WLL180T-x634
2nd Configuring the response time
Table 3: Configuring the response time
3. Zeiteinstellung
t I E r o f f
TOP
3rd Time delay setting
Table 4: Time configuration
d E L y
TOP
4. Detailed settings (expert mode)
To select the response time.
Select
and adjust
. The display reverts to the
Response time top menu.
Fastest setting 16 μs
H I g h
Quick setting 70 μs
F A S t
Standard setting 250 μs
S t n d
Large scanning range 2 ms
L o n g
Extra large scanning range 8 ms
S u P r
1)
Factory setting
To select the time delays.
Select
and adjust
. OFF reverts to initial display.
No time delay activated
o F F
OFF-Delay
o F d y
ON-Delay
o n d y
One-Shot
S H o t
ON/OFF delay
o n o F
One-shot delay
o n S h
1)
Factory setting
Time delays selectable from 0.1 ... 9,999 (0.1 ms ...
9,999 ms)
is for changing the time delay and
setting the time delay. The display then reverts to
the Time delay top menu.
o F d y 0 0 0 1
1)
1)
is for
8015556/1PJO/2024-10-07 | SICK