USE
The above Faults are only shown on the display; there
is no audible alarm signal.
Maximum freezer temperature exceeded alarm: If, after the
freezer reaches the set temperature, the temperature rises
to above 30℉, the alarm will sound, accompanied by
simultaneous flashing of the freezer temperature display.
Press any button to cancel the audible alarm. The flashing
will continue until the temperature falls below 30℉.
NOTE
The
main
compressor compartment.
POSITION
41℉ / 0℉
41℉ / 0℉
41℉ / 0℉
Super Freezing function
Super Cooling function
board
is
located
CONDITIONS
Summer or ambient
temperature
between 77℉ - 95℉
Spring, autumn or ambient
temperature
between 59℉ - 77℉
Winter or ambient
temperature
between 41℉ - 59℉
Super Freeze
Super Cool
ICE MAKER INSTRUCTIONS
Key Operation Instructions:
1) Short press the button to switch the ice machine on or
off.
2) When the machine is on, press and hold the button for
10 seconds to manually de-ice.
Lamp Status Description:
1) Switch On State: the light will fade on and then fade off.
in
the
2) Switch Off State: the light remains off.
3) Ice Full State: the light stays on continuously.
4) Drawer Removal: the light flashes slowly once every 0.5
seconds (1Hz)
Fault Status:
1) Ice Jam: the light flashes quickly once every 200 ms.
1 Ice Maker
2 Ice Maker Switch
1
2
Fig. 3