Installation and Operation Instructions
6�7 Operation
m
WARNING
CHAPTER 7
7�1 Functional description M1/100/120 (Standard model)
FUNCTION FOR
INSTALLER
7�2 Circuit diagram overview for M1/100/120 (Standard model)
Footnotes:
a) With regard to the connec-
MiniVent M1/100/120
m The safety instructions in chapter 1�3 must be observed!
In order to ensure the smooth functioning of the fan, the following must be checked on a regular basis:
– Appearance of dust or contaminant deposits in the housing or on the motor and impeller
– Freewheeling of the impeller
– Occurrence of excessive vibration and noise
In case of problems with one of the aforementioned points, maintenance must be carried out according
to the instructions in chapter 8.
The M1/100/120 MiniVent mini fan can be selectively operated with a commercially available light
switch in stage 1 or stage 2.
By controlling the speed with the on/off switch MVB (Accessories only for M1/100/120), the M1/100
can be used in two settings (75/90 m 3 /h) or the M1/120 can be used in two settings (150/170 m 3 /h).
M1/...
SS-915
N
L
1 2
a)
a)
L
N
1
2
a) Rückspg.! siehe MBV
tion of terminal 1 or 2, there
is reverse voltage at the ot-
her respective disconnected
terminal.
Room lighting or glow
lamps for operating dis-
plays, must only be connec-
ted via bipolar switch.
85089 001 SS-930 07.12.09
M1/100/120 with MVB
1
2
M1/...
a) Rückspg.! siehe MBV
N
L
1 2
a)
a)
L
N
11
MVB,
Art. Nr. 6091.002
L
L
EN
SS-930
I
0