Problem
Possible causes
F3-F8
Temperature sensor failure
F9-FD
Temperature sensor of the
IGBT failure.
E1/E2
Abnormal supply voltage
E3/E4
Temperature sensor of the
ceramic glass plate is high
Temperature sensor of the
E5/E6
IGBT is high
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and
damages to the induction hob.
9. Installation
9.1 Selection of installation equipment
Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be
preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-
resistant and insulated work surface material (wood and similar fibrous or
hygroscopic material shall not be used as work surface material unless
impregnated) to avoid the electrical shock and larger deformation caused by the
heat radiation from the hotplate. As shown below:
Note: The safety distance between the sides of the hob and the inner
What to do
Please contact the supplier.
Please contact the supplier.
Please inspect whether power
supply is normal.
Power on after the power
supply is normal.
Please restart after the
induction hob cools down.
Please restart after the
induction hob cools down.