Fire Safety
For reasons of fire safety is it important to observe the instructions below before installing the stove.
1. If the floor around the stove is made of combustible material, you must use a floor slab. The floor slab must
measure at least: - 50 cm from the stove on the front side of the door - 30 cm from the stove on the sides
of the door.
2. Keep at least a distance of 80 cm between the stove and combustible objects such as curtains, wooden
objects (cupboards and paintings) and glass objects. Keep the same distance from the flue tube.
3. Wooden construction parts within the radiation range of the stove (80 cm from the exterior of the stove)
must be covered with fireproof material.
4. If the flue tube goes through a ceiling and/or roof that consist of flammable materials, the ceiling and the
roof must be covered with fireproof materials all around (about 80 cm). Pay also attention to joisted floor
layers and any electric wiring.
5. Keep a distance of at least 50 cm (in all directions) between the stove and supporting steel construction
parts.
6. Shield off all combustible materials within a radius of 80 cm from the stove openings with non-combustible
materials.
7. Never cover the stove and flue pipes with combustible material (e.g. paper covering).
8. The wall behind the stove must consist of, or be insulated with, fire-proof materials. The insulation material
must resist a temperature of 700 °C and have a density of 80 kg/m3. Please see for insulation materials
table page 29).
9. Avoid heat transmission when placing the stove. Heat transmission of a burning stove can penetrate the
wall and even cause fire damage on the other side of the wall. Prevention is better than cure.
Installation
The Olaf Eco stove is tested in accordance with the
international EN 13240 standardization and has an extra
additional standardization for optimally environment-
friendly heating devices related to flue gases (Section 15a
B-Vg. Des BmfWA). The stove can be connected to a flue
tube to which several stoves are connected. The flue tube
has a diameter of 150 mm.
The heating device must be placed by an
!
acknowledged installer and according to the
installation instructions given below. The national
and local rules and regulations for placing and
using wood-burning stoves are equally applicable.
WANDERS does not give any guarantee if the
Olaf Eco is connected or installed incompletely or
incorrectly.
Supply of combustion air
The stove must have enough supply of fresh combustion
air. If necessary, make an extra air supply opening. An extra
opening for air supply is always required if:
the house has a heat recovery system.
the space where the stove is placed has a central
exhaust system.
there is a cooker hood in the same space.
The illustrations give the connections for external air supply.
100,00
Ø