General instructions

The Kanda is tested in accordance with international EN13229 standardization. This hearth can be connected
to a chimney to which several stoves are connected. The duct for the chimney has a diameter of 200 mm. The
connection to the convection system has a diameter of 150 mm.
The heating device must be placed by an acknowledged installer and according to the installation
!
instructions given below. The national and local rules and regulations for placing and using wood-
burning stoves are equally applicable. WANDERS does not give any guarantee if the Kanda is
connected or installed incompletely or incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2 dwellings.
Spaces where highly ammable or explosive materials are used.
Spaces where an exhaust system is used or where a mechanical exhaust system is placed, except when the
air supply is taken directly from outside to assure a hazardless combustion.

Preparation

The chimney ue

Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must rst have the chimney professionally cleaned
and checked by a quali ed chimney sweep company. Any cut-o valves or stop valves must be removed.
The ue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney ue must always end up in outlet area 1 (see the drawing and the table below)
At the time of placing the stove, the chimney ue must be clean, leak-proof and without obstructions, and
must have a diameter of 200 mm.
Any bends in the ue tube must not exceed 45 degrees.
Ensure that the chimney tube can discharge the ue gases adequately, properly and safely.
The values for calculating the chimney tube is given in the section on Technical Information, page 28.

Fire Safety

For reasons of re safety is it important to observe the instructions below before installing the stove.
1. If the oor around the stove is made of combustible material, you must use a oor slab. The oor slab must
measure at least: - 50 cm from the stove on the front side of the door - 30 cm from the stove on the sides
of the door.
24
1
3
3
A X
X > 23˚
1
X
3
500 mm
X < 23˚