Installation Instructions Olaf Eco; Preparation; The Chimney Flue - WANDERS Olaf Eco Mode D'emploi Et Instructions D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Soapstone is a natural product and the material may show some hairline cracks and the panels
!
may show some change in colour. This does not effect the operation of the stove and is therefore not
included in the warranty.

Installation Instructions Olaf Eco

The Olaf Eco is tested in accordance with the international EN 13240 standardization, and has an extra
additional standardization for optimally environment-friendly heating devices related to flue gases (Section
15a B-Vg. Des BmfWA). The stove can be connected to a flue tube to which several stoves are connected. The
flue tube has a diameter of 150 millimetres.
The heating device must be placed by an acknowledged installer and according to the installation
!
instructions given below. The national and local rules and regulations for placing and using wood-
burning stoves are equally applicable. WANDERS does not give any guarantee if the Olaf Eco is
connected or installed incompletely or incorrectly.
It is not allowed to place the stove in:
Arcades and corridors accessible to the public.
Stairwells, except in buildings with no more than 2 dwellings.
Spaces where highly flammable or explosive materials are used.
Spaces where an exhaust system is used or where a mechanical exhaust system is placed, except when the
air supply is taken directly from outside to assure a hazardless combustion.

Preparation

The chimney flue

Before placing the stove you must observe the following points:
If the stove is connected to an existing chimney, you must first have the chimney professionally cleaned
and checked by a qualified chimney sweep company. Any cut-off valves or stop valves must be removed.
The flue tube of the stove must be connected with the chimney without diversions.
The underpressure in the chimney must be at least 12 Pa or 0.12 mbar.
The chimney flue must always end up in outlet area 1 (see the drawing below)
At the time of placing the stove, the chimney flue must be clean, leak-proof and without obstructions, and
must have a diameter of 150 mm.
Any bends in the flue tube must not exceed 45 degrees.
Ensure that the chimney tube can discharge the flue gases adequately, properly and safely.
24
1
3
3
A X
X > 23˚
1
X
500 mm
3
X < 23˚

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Oiaf eco round

Table des Matières