Steam Supply Connections; Control Valves (Sakv******) Kits For Pressurized Steam Supplies; Fitting Kits (Sakr******) For Threaded Control Valves; Kit Attuatori Per Valvole Di Regolazione - Carel ultimateSAM SAB Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

4.1 Control valves (SAKV******) kits for
pressurized steam supplies
A control valve is needed to regulate the fl ow of pressurized steam to an
ultimateSAM distributor. Actuators for the control valve are sold separately.
If a valve and actuator kit was not ordered with the ultimateSAM distributor,
refer to the design manual for information on how to size and select a
control valves and actuators. Information on actuators is provided in section
4.2. The codes for valve kits are shown in table 4.a.
SAKV
0
2
1

ID prefi x
0
0
ƒ
Material
F = Cast iron
S = Stainless steel
0 = Brass (only for North America)
Operating
0 = Up to 1 bar (15psi) (only for North America)
pressure
H = 1-4 bars (15-50psi) (only for North America)
F = 0.1-4 bars (1.45-50psi )
Nominal size
A= 0.4
Kv (EU)
B= 0.63
Cv (US)
C= 1
D= 1.6
E= 2.5
F= 4
G= 6.3
H= 10
I= 16
J= 25
K= 40
L= 63
Region
U = North America
0 = Other
---
---
Specifi cs regarding the inlet connection on available control valves are
shown in Table 4.b.
Inlet-Outlet Connections
Material, Pressure, Region Codes
*****FH*0* -
Valve Size
*****SF*0*
SAKV0**C*0
Flange DN 15
SAKV0**D*0
Flange DN 15
SAKV0**E*0
Flange DN 15
SAKV0**F*0
Flange DN 15
SAKV0**G*0
Flange DN 20
SAKV0**H*0
Flange DN 25
SAKV0**I*0
Flange DN 32
SAKV0**J*0
Flange DN 40
SAKV0**K*0
Flange DN 50
SAKV0**L*0
Flange DN 65
If the inlet pressure to the control valve is greater than 0.7 bar (10 psig),
the valve may generate signifi cant noise due to the near sonic velocity of
the steam. (See section 6.1 of the design manual for more information.)
Because the noise and coincident vibration may shorten valve life, frequent
inspections of the valve may be required.
For information about the weight, dimensions, construction materials, and
rangeability of each valve, see the "Technical specifi cations" manual.

4. STEAM SUPPLY CONNECTIONS

x
x
x
x 0
3
4
5
6
7
Tab. 4.a
*****00*U*
*****0H*U*
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
½" NPT Fem.
¾" NPT Fem.
¾" NPT Fem.
1" NPT Fem.
1" NPT Fem.
1¼" NPT Fem.
1¼" NPT Fem.
1½" NPT Fem.
1½" NPT Fem.
2" NPT Fem.
not available
not available
not available
Tab. 4.b
4.2 Fitting kits (SAKR******) for threaded
control valves
Nota: For fl anged control valves, the installer must provide the
appropriate fi ttings and piping to connect the valve to the
ultimateSAM distributor. For control valves having threaded connections,
optional fi tting kits are available to facilitate the connection of the valve to both
the distributor inlet and the steam traps and strainers (section 4.3). The codes for
the fi tting kits are shown in table 4.c.
SAKR
1

Prefi sso
0
0
ƒ
Materiale
F = Ghisa - S = Inox
Taglia
24= ½"
Tubo
44= 1"
Tubo
64= 1 ½" Tubo
Mercato
U = North America
---
---
Both iron and stainless steel fi tting kits for the North American region have
NPT threads. The list of threaded pipe fi ttings provided in each kit is shown
in table 4.d.
Fitting List for SAKR0***U0
Pipe Size
Bushing
(NPT)
F-M (size)
******24**
2 (½"x1")
******34**
2 (¾"x1")
******44**
n/a
******54**
2 (1¼"x2")
******64**
2 (1½"x2")
******84**
n/a

4.3 Kit attuatori per valvole di regolazione

Each control valve needs an actuator to control its motion. The system for
identifying actuator kits is shown in Table 4.e. Note: Not all of the possible
combinations shown on the table are available. Tables 4.f and 4.g indicate
which electronic or pneumatic actuator can be paired with which control
valve.
SAKA
1

ID prefi x
0
0
ƒ
Type:
E = Electronic
01 Sequential # - 02 - ---
Identifi er:
U = North America
Region:
---
---
Electronic actuator selection
Valve Size
*****FH*0*
SAKV0**A*0
non dispon.
SAKV0**B*0
SAKV0**C*0
SAKA0E0200
"SAKV0**D*0
SAKA0E0200
SAKV0**E*0
SAKV0**F*0
SAKA0E0200
SAKV0**G*0
SAKA0E0200
SAKV0**H*0
SAKA0E0200
SAKV0**I*0
SAKA0E0200
"SAKV0**J*0
SAKA0E0200
SAKV0**K*0
SAKV0**L*0
SAKA0E0200
Nota: for valve types "*****FH*0*" the actuator is included in the
valve kit, so the code (SAKAE00200) indicated above is to be used
when ordering a spare actuator only.
19
"ultimateSAM - user" +03U0070EF - rel. 1.0 - 23.05.2013
ENG
xx
0
x
U
0
3
4
2
5
6
34= ¾"
Tubo
54= 1 ¼" Tubo
84= 2"
Tubo
3" Nipple
Union
M-M (size)
F-F (size)
2 (1/2")
1 (1")
2 (3/4")
1 (1")
2 (1")
1 (1")
2 (1 1/4")
1 (2")
2 (1 1/2")
1 (2")
2 (2")
1 (2")
xx
0
x
x
0
3
4
2
5
6
P = Pneumatic
0 = Others
Material, Region Codes
*****SF*0*
*****00*U*
*****0H*U*
non dispon.
SAKAE001U0
non dispon.
SAKA0E0300
SAKAE001U0
SAKAE002U0
SAKA0E0300
SAKAE001U0
SAKAE002U0
SAKA0E0300
SAKAE001U0
SAKAE002U0
SAKA0E0300
SAKAE001U0
SAKAE002U0
SAKA0E0300
SAKAE001U0
SAKAE002U0
SAKA0E0300
SAKAE002U0
SAKAE002U0
SAKA0E0300
SAKAE002U0
not available
SAKA0E0300
not available
not available
Tab. 4.c
Tab. 4.d
Tab. 4.e
Tab. 4.f

Publicité

Chapitres

Table des Matières
loading

Ce manuel est également adapté pour:

Ultimatesam satUltimatesam sa0

Table des Matières