Télécharger Imprimer la page

Bosch GKF18V-25 Consignes D'utilisation/De Sécurité page 19

Publicité

cutting depth is reached on the Depth
Scale 5.
5. Rotate the Palm Router 1 clockwise
until it locks into the Tilt Base 31 and
cannot rotate clockwise further
6. Use the Microfine Adjustment Wheel 17
to precisely reach the desired fine depth
on the Depth Scale 5. (Unavailable for
Offset Base PR004.)
7. Close the Clamping Lever 16
Note: The tightness of the clamping
lever can be adjusted as needed, see
section "Adjusting the Clamping Lever"
on page 25.
Adjusting the Angle of the Tilt Base
(Fig. 16)
Note: The total tilt range is 75°, from 45°
forward to 30° backward.
1. Loosen the two Wing Screws 32.
2. Adjust to the desired angle using the
Angle Scale 33 on the side of the
base; there are detents at every 7.5°.
Whenever possible, the base should be
positioned with the Palm Router 1 tilted
toward the closed end of the Tilt Base
31.
3. Tighten the Wing Screws 32. Be careful
not to over-tighten or the base may be
damaged.
Removing the Palm Router from
the Tilt Base
(Fig. 15)
Open the Clamping Lever 16
steps 1-4 from section "Installing the Palm
Router to the Tilt Base" on page 18.
Assembly
Fig. 16
.
.
then reverse
31
32
33
32
19

Publicité

loading

Ce manuel est également adapté pour:

Gkf18v-25n professional