Fixed Base (GKF001) and
Accessories
Installing the Palm Router to the
Fixed Base
(Fig. 7)
1. Open the Clamping Lever 16
2. Align the slot on the Palm Router 1 to
the Depth Setting Indicator 18 on the
Fixed Base 14
3. Slide the Palm Router 1 into the Fixed
Base 14. The Unlock Symbol 12 indi-
cates you are in the rough depth adjust-
ment setting. Move the Palm Router
1 up or down until the approximate
cutting depth is reached on the Depth
Scale 5. Rotate the Palm Router 1 clock-
wise until it locks into the Fixed Base 14
; the Depth Setting Indicator 18 will
align with the Lock Symbol 13 on the
router.The Lock Symbol 13 indicates you
are in the fine depth adjustment setting.
4. Use the Microfine Adjustment Wheel 17
to precisely reach the desired fine depth
on the Depth Scale 5
Offset Base PR004).
5. Close the Clamping Lever 16
Note: The tightness of the clamping
lever can be adjusted as needed, see
section "Adjusting the Clamping Lever"
on page 25.
Fig. 7
12
5
16
.
.
(unavailable for
.
13
1
14
17
Assembly
Removing the Palm Router from
the Fixed Base
1. Open the Clamping Lever 16 then
reverse steps 1-3 in "Installing the Palm
Router to the Fixed Base" on page 15.
Extraction Hood and Chip
Protection Guide (optional
accessories)
(Fig. 8)
1. Attach the Fixed Base Edge Routing
Dust Extraction Hood 24 to the back of
the Fixed Base 14
2. Secure Fixed Base Edge Routing Dust
Extraction Hood 24 in place using the
Rear Accessory Thumb Screw 51
3. Place the Fixed Base Chip Protection
Guard 25 over the Fixed Base 14 open-
ing so that the pin on the right side
snaps into the hole on the base
4. Secure the guard in place, on the left
side of the base, with the Dust Extrac-
tion Thumb Screw 53
5. Connect the hood to the vacuum using
either a friction fit nozzle or the Bosch
quick click system.
Fig. 8
14
53
18
.
.
25
.
.
51
24
15