Conversion To A Different Gas Type; Nozzle Table / Overview - Salvis Master Série Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.

Conversion to a Different Gas Type

Observe the safety instructions, refer to page 18, chapter 1.
D For conversion to different gas types, use original nozzles only.
. After conversion to a different gas type and maintenance works:
− Check all gas-bearing components for leak tightness (leakage spray),
− attach a label stating gas type and gas pressure (mbar) to the gas range.
. Read off the data required for conversion from the nozzle table/overview, refer to page 25,
chapter 7.1
7.1

Nozzle table / overview

Nozzle type
Gas type
II
DE –
2ELL 3B/P
Natural gasE
Primary pressure
20 mbar
(DE)
Natural gasLL
Primary pressure
20 mbar
(DE)
Liquid gas B/P
Primary pressure
50 mbar
(DE)
II
GB –
2H 3+
Natural gasH
Primary pressure
20 mbar
(GB)
Liquid gas 3+
Primary pressure
29/37 mbar
(GB)
II
FR –
2E+ 3B/P
Natural gasE+
Primary pressure
20/25 mbar
(FR)
Liquid gas B/P
Primary pressure
50 mbar
(FR)
Outer nozzle
Refer to page 27, chap­
ter 7.2
ø 1,85 mm
ø 2,00 mm
ø 1,12 mm
ø 1,85 mm
ø 1,3 mm
ø 1,85 mm
ø 1,12 mm
Reduction nozzle
Refer to page 27, chap­
ter 7.3
ø 1,05 mm
ø 1,05 mm
ø 0,60 mm
ø 1,05 mm
ø 0,65 mm
ø 1,05 mm
ø 0,60 mm
en
Pilot burner nozzle
For pilot burner nozzle
replacement, refer to
page 28, chapter 7.4
Two bores of
ø 0.25 mm each
Two bores of
ø 0.25 mm each
ø 0,20 mm
Two bores of
ø 0.25 mm each
ø 0,20 mm
Two bores of
ø 0.25 mm each
ø 0,20 mm
25 / 56

Publicité

Table des Matières
loading

Table des Matières