4.2
Cleaning the stainless-steel surfaces
. If aggressive cleansers have been used, thoroughly wipe down the cleaned components and
surfaces with a clean, damp dish cloth, without the use of a cleaning agent.
. Clean all stainless-steel surfaces with fat-dissolving cleaning agents or special stainless-
steel care agents.
. Rub the cleaned parts and surfaces dry with a soft cloth.
5.
Malfunctions and Rectification
Should malfunctions occur with the device, please check them with the help of the followingta
ble:
Malfunction
The pilot light cannot be lit.
The pilot light is extin
guished upon the gas gov
ernor's release.
Should you not be able to rectify the malfunction,
- Switch the device off.
- Close the gas tap.
- do not open the housing,
- inform the customer service.
Cause
The gas tap is closed.
The service valve is closed.
The pilot burner is contamin
ated.
The thermal element is contam
inated.
The gas governor was not
pressed in long enough.
The thermal element is defect
ive.
Open
Close
Rectification
Open the gas tap.
Open the service valve.
inform the customer service.
inform the customer service.
Keep the gas governor pressed
for approx. 5 - 10 seconds to
assure the thermal element's
sufficient heating and avoid an
interruption of the gas supply.
inform the customer service.
en
23 / 56