EN
8 PROGRAMMING THE REMOTE CONTROLS
8.1 Memorising the 2- or 4-button remote control for
pedestrian opening - Fig. 30
[1]. Press and hold (2 s) the PROG button (7, Fig. 3).
The red indicator will come on permanently.
[2]. Press the PROG button a second time.
The red indicator light flashes once slowly.
[3]. Press the button of the remote control that will open the gate for pedestrians.
The red indicator light flashes; the remote control has been memorised.
In pedestrian opening mode, the gate operates for 7 seconds.
8.2 Memorising the 2- or 4-button remote control to control
the auxiliary output - Fig. 31
[1]. Press and hold (2 s) the PROG button (7, Fig. 3).
The red indicator will come on permanently.
[2]. Press the PROG button a second time.
The red indicator light flashes once slowly for 0.5 seconds.
[3]. Press the PROG button a third time.
The red indicator light flashes once very slowly for 2 seconds.
[4]. Press the button on the remote control to control the auxiliary output.
The red indicator light flashes; the remote control has been stored.
9 CLEARING THE REMOTE CONTROLS AND ALL
SETTINGS
9.1 Clearing the memorised remote controls - Fig 32
Causes all stored remote controls to be cleared.
9.2 Clearing the programming - Fig. 33
Clears the programming: offset between the gate leaves, slowdown zone at end of travel.
10 TROUBLESHOOTING THE SAFETY EDGE
Disconnect the safety edge and create a bridge between terminals 14 and 15 of the motor
electronics.
The motorisation is operating with no safety device.
Once troubleshooting has been carried out:
- remove the bridge between terminals 14 and 15 of the motor's electronics,
- set the dipswitch 10 to ON,
- test the safety edge.
7
DANGER
11 TECHNICAL DATA
GENERAL SPECIFICATIONS
Power supply
Max. power consumption
Thrust force
Climatic operating conditions
Somfy radio frequency
Number of memorisable channels
CONNECTIONS
Type
Safety input
configurable during
Compatibility
closing
Wired control input
Orange light output
Safety input test output
Accessories power supply output
Offset aerial input
OPERATION
Automatic closing mode
Orange light warning
Coupling speed when closing
Elixo 500 230V RTS / Elixo 800 230V RTS
220/230 V - 50/60 Hz
Elixo 500: 400 W - Elixo 800: 300 W
Elixo 500: 500 N - Elixo 800: 800 N
- 20° C / + 60° C - IP44
433.42 MHz
< 10 mW
128
Dry contact: NC
TX/RX photoelectric cells - Reflex cell - Safety
edge
Dry contact: NO
220/230 V - 50/60- 60 Hz
Yes: autotest for cell active during closing
24 Vac - 315 mA max
Yes: compatible with RTS aerial
(part no. 2400472)
Yes: programmable timed reclosing from 0
to 120 s
Programmable: without or with warning
(fixed at 2 s)
By default 33% of normal speed
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.