Elixo 500 230V RTS / Elixo 800 230V RTS
7 ADVANCED PARAMETER SETTING
The change in dipswitch status is taken into account immediately.
The default position of the dipswitches is indicated in bold.
7.1 Motor torque - Dipswitches 1 and 2
DIP - SW 1
OFF
Motor torque
OFF
adjustment
ON
ON
If the "Motor torque setting" is modified, the installer must check that obstacle detection
complies with appendix A of standard EN 12 453.
Failure to follow this instruction may result in serious injury, e.g. due to crushing by the gate.
7.2 Motor direction of rotation - Dipswitch 3
DIP - SW 3
Setting
OFF
Motor installed to the le of the gate
ON
Motor installed to the right of the gate
7.3 Auxiliary output - Dipswitch 4
DIP - SW 4
Setting
OFF
Lighting
ON
Electric lock
7.4 Lighting time delay - Dipswitch 5
DIP - SW 5
Setting
OFF
30 seconds
ON
120 seconds
7.5 Wire input operating modes - Dipswitch 6
DIP - SW 6
Setting
OFF
Complete/pedestrian opening control
ON
Opening/closing control
7.6 Operating modes - Dipswitches 7 to 9
DIP -
DIP -
DIP -
Setting
SW 7
SW 8
SW 9
Sequential
OFF
OFF
OFF
Each press on the remote control button causes the
motor to move (initial position: gate closed) as per the
following cycle: open, stop, close, stop, open..
Sequential + automatic timed close
OFF
OFF
ON
Operation in automatic closing mode is only authorised
if photoelectric cells with autotest function are
installed (see Fig. 21B).
In sequential mode with automatic timed close:
- the gate closes automatically a er the time delay
programmed with the TIME potentiometer,
- pressing a button on the remote control interrupts the
movement taking place and the timed close (the gate
remains open).
Copyright© 2017 SOMFY ACTIVITES SA. All rights reserved.
DIP - SW 2
Setting
OFF
100% torque
ON
75% torque
OFF
50% torque
ON
25% torque
WARNING
Semi-automatic
- pressing the button on the remote control while the gate is
OFF
ON
OFF
opening will stop the gate,
- pressing a button on the remote control during closing causes
it to reopen.
Automatic
OFF
ON
ON
In automatic mode, the final position of the gate will always be
the closed position.
Operation in automatic closing mode is only authorised
if photoelectric cells with autotest function are
installed (see Fig. 21B).
- the gate closes automatically a er the time delay
programmed with the TIME potentiometer,
- pressing a button on the remote control during opening has
no effect,
- pressing a button on the remote control during closing
causes it to reopen,
- pressing a button on the remote control during the closing time
delay restarts the time delay (the gate will close when the new
time delay has elapsed).
If there is an obstacle in the cells' detection zone, the gate will
not close. It will close once the obstacle is removed.
Automatic + cell blocking
ON
OFF
OFF
In automatic mode, the final position of the gate will always be
the closed position.
Operation in automatic closing mode is only authorised
if photoelectric cells with autotest function are
installed (see Fig. 21B).
A er the gate is opened, movement in front of the cells (if
active cell input during closing is activated) will close the gate
a er a short time delay (fixed at 2 seconds).
If there is no movement in front of the cells, the gate will close
automatically a er the timed close programmed in with the
TIME potentiometer.
If there is an obstacle in the cells' detection zone, the gate will
not close. It will close once the obstacle is removed.
Deadman's wired control
ON
ON
ON
The gate can only be controlled by continuous action on a wired
control: opening on OPENING control input, closing on CLOSURE
control input,
The pedestrian and radio controls are inactive.
There is no slowdown zone when the deadman's wired control
is operating,
This operating mode can be activated without programming.
7.7 Safety edge autotest - Dipswitch 10
DIP - SW 10
Setting
OFF
Without autotest
ON
With autotest
7.8 Orange light warning - Dipswitch 11
DIP - SW 11
Setting
OFF
Without warning
ON
With 2 s warning prior to movement
7.9 Cell autotest when closing - Dipswitch 12
DIP - SW 12
Setting
OFF
Without autotest
ON
With autotest: the autotest is only available for the cell
connected to the cell active during closing input.
7.10 Setting the timed close - Fig. 29
Set the timed close (up to 120 s delay) with the TIME potentiometer if the "Sequential +
automatic timed close", "Automatic" or "Automatic + cell blocking" operating mode is selected:
- Turn the potentiometer to the right to increase the time delay.
- Turn the potentiometer to the le to decrease the time delay.
EN
6