7 - FUNCTION / USE AND
PROGRAMMING
INTRODUCTION
The programming software permits the che-
cking of the following operations:
- handling of 2-3-4 coffee units
- simultaneous function of both coffee and
tea units
- cappuccino/milk function
- volumetric check on coffee measures
- timed tea measure check
- simulated measure programming
- filling level check and control
- system supervision through alarms
- continuos, delivery time-out and further
functions
- serial connection with accounting devices
- 16 X 2 LCD display (not rear-lit) for
functional state display.
Important: the last selection made always
appears on the display
7.1 COFFEE MEASURE
PROGRAMMING
The measured amounts of coffee may be
modified (by means of volumetric checking)
and memorized as follows:
- press key T5 (of keyboard relative to
group 1) and keep pressed for over 5
seconds and check that all the keyboard
leds come on. In which case, (by opera-
ting on the keyboard relative to group 1)
all the units will be programmed, while
by pressing key T5 of another unit, only
the programming of the unit on which
one is operating is possible.
IMPORTANT !! The settings made on unit 1
(operating on the first keyboard) will be auto-
matically copied on to all the other units.
Keyboard symbols:
T1
Single espresso coffee
T2
Double espresso coffee
T3
Single long coffee
T4
Double long coffee
39
T5
Programming/continuos
T6
Cappuccino
T7
Milk
T8
Tea (hot water)