9.5 Erp imformation
14HP
Cooling mode:
Information requirements for air-to-air conditioners
Model(s):MOUG-140HD1N1-R
Test matching indoor units form, cassette: 2×MIH45Q4N18 + 4×MIH80Q4N18
Outdoor side heat exchanger of air conditioner: air
Indoor side heat exchanger of air conditioner: air
Type: compressor driven
Driver of compressor: electric motor
Item
Symbol
Rated cooling capacity
P
rated,c
Declared cooling capacity for part load at given outdoor
temperatures T
and indoor 27/19°C(dry/wet bulb)
j
T
=+35°C
P
j
T
=+30°C
P
j
T
=+25°C
P
j
T
=+20°C
P
j
Degradation
co-efficient for air
C
conditioners(*)
Off mode
P
Thermosat-off mode
P
Capacity control
Sound power
level, outdoor
GWP of the refrigerant
Contact details
(*)If C
is not determined by measurement, then the default degradation coefficient of heat pumps shall be 0.25.
dc
Where information relates to multi-split air conditioners, the test result and performance data may be obtained on the basis
of performance of the outdoor unit, with a combination of indoor unit(s) recommended by the manufacturer or importer.
Value
Unit
kW
40.00
kW
40.00
dc
kW
29.48
dc
kW
18.95
dc
kW
7.88
dc
--
0.25
dc
Power consumption in modes other than "active mode"
kW
0.005
OFF
kW
0.005
TO
Other items
variable
L
dB
82
WA
kg CO
2 eq
2088
(100years)
Item
Seasonal space cooling
energy efficiency
Declared energy efficiency ratio or gas utilisation efficiency
/auxiliary energy factor for part load at given outdoor
temperatures T
T
=+35°C
j
T
=+30°C
j
T
=+25°C
j
T
=+20°C
j
Crankcase heater mode
Standby mode
For air-to-air air conditioner:
air flow rate, outdoor
measured
Symbol
Value
Unit
η
%
263.0
s,c
j
EER
2.54
--
d
EER
4.36
--
d
EER
8.21
--
d
EER
13.60
--
d
P
kW
0.04
CK
P
kW
0.005
SB
--
m
/h
3
12500
V.1