User manual
OPTIONAL REMOTE CONTROL
• Analogue remote control RC-HA1 (P.N. RC-HA1) for TITANIUM 230/400:
An analogue remote control can be connected to the power source via the connection (I-11).
This remote control allows the current to be adjusted between 50 - 100% of the set current. In this configuration, all of the power source's modes
and features can be accessed and configured.
• Analogue remote control RC-MMA/DEGAUSS (P.N. 066496):
An analogue remote control can be connected to the power source via the connector (I-4).
In MMA only, the control allows the current to be varied from 50% to 100% of the current set via a potentiometer, the welding polarity to be reversed
via the polarity switch and the welding current source to be activated or deactivated to protect the welder during handling.
• Remote control RC-MMA/TIG-FA1 pedal (P.N. 045682) for TITANIUM 230/400 or RC-FA2 (P.N. 083356) for TITANIUM 321:
A remote-control pedal can be connected to the power source via the connection (I-11).
The pedal allows you to adjust the current from the minimum to 100% of the set welding current. In TIG mode, the power source will only work in 2T
mode. Furthermore, the current's rise and fall are no longer managed by the power source (inactive functions) but by the user using the foot pedal.
• Remote HMI - RC-HD2 digital remote control (P.N. 062122) for TITANIUM 230/400 or RC-HD3 (P.N. 079700) for TITANIUM 321 :
TITANIUM 400: A digital remote control can be connected to the power source via the connection (I-12).
TITANIUM 321: A digital remote control can be connected to the power source via the connection (I-6).
TITANIUM 230: A digital remote control can be connected to the power source via the optional NUM-1 kit (I-7).
This remote control is designed for MMA and TIG welding processes. It allows the user to remotely adjust the welding unit. An ON/OFF button is
used to switch on or off the digital remote control. When the digital remote control is switched on, the power source's HMI will display the current
and voltage values. As soon as the HMI is turned off or disconnected, the welding machin'es HMI is reactivated.
Connectivity for TITANIUM 230/400:
This product is equipped with a female remote control terminal.
The purposely designed, seven-prong, male connector (optional extra, PN: 045699) allows different types of remote control to be connected. For
wiring, follow the diagram below.
REMOTE CONTROL TYPE
Foot pedal
C5
Connectivity for TITANIUM 321:
This product is equipped with a female remote control terminal.
The purposely designed, seven-prong, male connector (optional extra, PN: 046238) allows different types of remote control to be connected. For
wiring, follow the diagram below.
Type of remote control
Foot pedal
OPTIONAL COOLING UNIT
Compatibility
TITANIUM 230 AC/DC FV
TITANIUM 321 AC/DC
TITANIUM 400 AC/DC
The machine will automatically detect the cooling unit. To deactivate the cooling unit (OFF), please refer to the HMI's user manual.
The following safeguarding measures are supported by the cooling unit to ensure that the torch and user are protected:
• Minimum coolant level
• Minimum coolant flow rate through the torch
• Thermally protected coolant
36
Translation of the original
instructions
Manual remote control
Wire description
VCC
Common/Earth
Interrupteur
Switch
Part number
Name
070820
KOOLWELD 1
083363
KOOLWELD 3
013537
WCU 1KW C
Wire type
10 V
Cursor
Common / Earth
Switch
AUTO-DETECT
ARC ON
REG I
Pin
4
1
2
5
4
6
7
5
External view
Cooling power
Capacity
3 L
1,000 W
5.5 L
5.5 L
TITANIUM
Associated connector pin
A
G
F
A
B
C
E
D
E
D
C
F
External view
G
3
2
1
Power-supply voltage
24 V
400 V +/- 15%
400 V +/- 15%
B