User manual
Advanced settings, only available in «Advanced» display mode:
Advanced settings
HF duration
0.01 - 3 s
HF level
COMPATIBLE TORCHES AND TRIGGER ACTIONS
Single button
B
For the one-button torch, the button is called the «main button».
On the two-button torch, the first button is called the «main button» and the second is called the «secondary button».
DB
• 2T
P
t
Main button
T1
t
Main button
T1
t
• 4T
Main button
T1
t
t
t
Main button
T1
T2
Main button
T1
T2
Main button
T1
T2
• 4T LOG
<0.5s
t
t
t
Main button
T1
T2
Main button
T1
T2
Main button
T1
T2
or
Secondary button
For double-button or double trigger torches with a potentiometer, the «upper» trigger carried out the same function as the single-trigger torch. The
«lower» trigger switches the machine to a cold current when it is held down. The torch's potentiometer, when present, allows the usedr to adjust the
welding current from 50 - 100% of the displayed value. The «Up & Down» feature allows the current to be adjusted at the torch.
Translation of the original
instructions
Settings
Description
HF time before stopping
0 - 10
Index setting the voltage from 5 - 14 kV
B
Double button
DB
P
t
t
T2
t
T2
T2
t
t
t
T4
T3
T4
T3
<0.5s
<0.5s
>0.5s
T4
T3
<0.5s
<0.5s
>0.5s
<0.5s
>0.5s
t
t
t
T4
T3
T4
T3
T4
T3
B
DB
Double button & potentiometer
P
T1 - The main button is pressed, the welding cycle starts (Pre Gas,
I_Start, UpSlope and welding).
T2 - The main button is released, the welding cycle is stopped
(DownSlope, I_Stop, Post Gas).
When the double-button torch is in 2T mode, the secondary button
is operated in the same way as the main button.
T1 - The main button is pressed, the cycle starts from the Pre Gas
and stops in the I_Start phase.
T2 - The main button is released, the cycle continues to UpSlope
and welding processes.
T3 - The main button is pressed, the cycle goes into DownSlope
and stops in the I_Stop phase.
T4 - The main button is released, the cycle ends with Post Gas.
NB: for torches, double-button torches and double-button torches
with a potentiometer
=> «high/welding current» button and active potentiometer, «low»
button inactive.
T1 - The main button is pressed, the cycle starts from the Pre Gas
and stops in the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope
and welding.
LOG: This operating mode is used in the welding phase:
- A brief push of the main button (< 0.5 s) switches the current from
I_Welding to I_Cold and vice versa.
- When the secondary button is held down, the current switches
from I_Welding to I_Cold.
- When the secondary button is held down, the current switches
from I_Cold to I_Welding.
T3 - Holding down the main button (> 0.5 s) makes the cycle go into
DownSlope and then stop in the I_Stop phase.
T4 - The main button is released, the cycle ends with Post Gas.
TITANIUM
Up & down
UP
Down
31