Using the machine interface
Processes
Access to some welding processes depends on the product:
TIG
(GTAW)
Arc welding with non-stick electrode, in a protective gas atmosphere
MMA
(SMAW)
Arc welding with coated electrode
Settings
(User settings)
User Level
- Easy: reduced display and functionality (no access to the welding cycle).
- Expert: full display, allows the user to adjust the timing of the different welding cycle phases.
- Advanced: full display, allows the user to adjust all the welding cycle settings.
Language
Choice of the interface language (English, French, German, etc).
Brightness
Adjusts the interface screen's brightness (setting from 1 [very dark] to 10 [very bright]).
User Code
Customise the user's access code to safely lock the machine (default 0000).
Tolerance I (current)
Current tolerance control:
OFF : Freely adjustable, the current setting is not limited.
± 0A : no tolerance, current limitation.
± 1A> ± 50A : The setting range at which the user can adjust their current.
System
Machine name
Information about the device's name and the option to customise it can be reached by pressing
Clock
Setting the time, date and format (AM/PM).
Cooling system
- OFF : The cooling unit is switched off.
- ON : The cooling unit is permanently switched on.
- AUTO : automatic control (activated during welding and deactivated 10 minutes after welding has ended)
PURGE
: a function designed to purge the cooling unit or to filling beams, during which the safeguards are
disabled (see the cooling unit manual to purge your product safely).
Validation
The validation of welding equipment is an operation to check the performance of the product in relation to its settings.
The CALIWELD calibration case (option, ref. 060456) is used to issue a validation report and to verify the welding values.
Press push-button no. 3 ( ) to display the most recent validation date of the item.