3-wire receptacle (NEMA Type 10-30R)
Go to "Power Supply Cord Connection" section.
Direct Wire
4-wire direct
Go to "Direct Wire Connection" section.
3-wire direct
Go to "Direct Wire Connection" section.
Power Supply Cord Connection
WARNING
Fire Hazard
Use a new UL listed 30 amp power supply cord.
Use a UL listed strain relief.
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center
terminal (silver).
Ground wire (green or bare wire) must be connected to
green ground connector.
Connect remaining 2 supply wires to remaining
2 terminals (gold).
Securely tighten all electrical connections.
Failure to do so can result in death, fire, or
electrical shock.
20
Remove Terminal Block Cover
Remove hold-down screw (D) and terminal block cover (A).
C
B
E
A. Terminal block cover
B. External ground conductor screw
C. Center terminal block screw
Power Supply Cord Strain Relief
1. Insert strain relief.
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening (B) so
that one tab is pointing up (A) and the other is pointing down (D),
and hold in place. Tighten strain relief screws just enough to hold
the two clamp sections (C) together.
2. Insert power cord into strain relief.
Put power supply cord through the strain relief. Be sure that the
wire insulation on the power supply cord is inside the strain relief.
The strain relief should have a tight fit with the dryer cabinet and
be in a horizontal position. Do not further tighten strain relief
screws at this point.
Connecting 4-Wire Connection: Power Supply
Cord
IMPORTANT: A 4-wire connection is required for mobile
homes and where local codes do not permit the use of 3-wire
connections.
D
A
D. Hold-down screw
E. Neutral ground wire
A
B
C
D