Lift the rear of the control panel (1) with a
slight tug and remove it from the robotic
mower. It remains connected to the
machine via a spiral cable.
160
Inserting the control panel:
Stow the spiral cable (1) in the housing
compartment. Tilt the control panel
backwards slightly, insert the retainers (2)
in the recesses in the housing (3), then
press down the control panel at the front
and allow to engage.
15.3 Adapting the programming
Current programmes can be seen in the
mowing plan or, in the case of the
RMI 632 C, RMI 632 PC models, in the
iMOW® app. (
10.)
The mowing plan is calculated based on
the size of the mowing area during
installation or during the creation of a new
mowing plan.
The active times and the mowing
duration can be changed individually.
With the mow plan type Standard the
robotic mower mows and charges
precisely within the active times, with the
mow plan type Dynamic the necessary
mowing operations are automatically
distributed over the possible active times.
If required, several mowing or charging
operations can run during an active time. If
required, the edge of the mowing area can
be cut automatically at regular intervals.
(
11.13)
Up to three different active times per day
are possible. (
11.7)
If the robotic mower has to travel to
specific areas of the mowing area, starting
points must be defined. (
If the mow plan type Dynamic is
selected, not all the active times
may be necessary for optimal lawn
care under certain circumstances
(e.g. warm weather or generous
time window).
Changing the active times: (
– Additional active times for further
mowing operations.
– Adapting the time window, e.g. to
prevent mowing during the morning or
night.
– Omitting individual active times
because the mowing area is e.g. being
used for a party.
Extending the mowing duration: (
– There are areas which are not mown
sufficiently, e.g, because the mowing
area has many corners.
0478 131 9954 C - EN
11.14)
11.7)
11.7)