the drive home. It then travels to the
perimeter wire and on to the docking
station.
Guide loops with an external docking
station:
To the right and left of the access to the
external docking station, two guide
loops (1) have to be installed at an angle of
90° to the perimeter wire.
Minimum clearance to access: 2 m
Guide loops with corridors:
To the right and left of the corridor access,
two guide loops (1) have to be installed at
an angle of 90° to the perimeter wire.
These must always be located in the part
0478 131 9954 C - EN
of the mowing area that can only be
accessed via a corridor.
Minimum clearance to corridor access:
2 m
If several consecutive corridors are
installed, guide loops must be
installed in each of the relevant
mowing areas.
Installation of a guide loop:
Guide loops must not be installed in the
vicinity of corners.
Minimum clearance to corners: 2 m
Install the guide loop in the mowing area
as shown. The perimeter wire (1) must be
fastened to the ground with two fixing pins
at the edge A and must not be crossed.
Minimum length: 100 cm
Wire routing pin to pin B.
● Attach the guide loop to the ground with
a sufficient number of fixing pins.
12.13 Accurate mowing along edges
A strip with a width of up to 26 cm is
left unmown along high obstacles. If
necessary, edging stones can be
laid around high obstacles.
Minimum width of edging stones:
Route the perimeter wire at a clearance of
33 cm to the obstacle. To ensure that the
lawn edge is mown completely, the edging
stones must have a width of at least
26 cm. If wider edging stones are laid, the
lawn edge is cut even more precisely.