• The flow of extracted air must be clean (that is free of
grease, soot, chemical and corrosive agents and
explosive or flammable mixtures).
• Keep the appliance intake and outlet grilles free to
ensure optimum air flow.
• Maximum operating temperature: 50°.
• Specifications for the power supply must correspond
to the electrical data on ID plate A (Fig.1).
1 1
CODICE COLORI
COLOR CODE
1 NERO - BLACK
2 BLU - BLUE
3 ROSSO - RED
5 GRIGIO - GREY
6 BIANCO - WHITE
7 MARRONE - BROWN
ALIMENTAZIONE
SUPPLY
L
N
BY-PASS
CODICE COLORI
M
COLOR CODE
6
1
2
1 NERO - BLACK
2 BLU - BLUE
3 ROSSO - RED
5 GRIGIO - GREY
6 BIANCO - WHITE
7 MARRONE - BROWN
BY_PASS ON
ALIMENTAZIONE
SUPPLY
L
N
10
M
M
6
1
2
3
5
6
1
2
3
5
3
L2
N1
3
L2
N1
7
1
2
7
1
2
V.MIN
V-MAX
HRI ONE
SUPPLY
EXHAUST
M
M
3
5
6
1
2
3
5
6
1
2
3
5
7
1
2
7
1
2
A
A: spostare il cavo blu del motore dell'aria di rinnovo
sul morsetto libero .
Move the connection of the motor blue cable
relevant to supply air on the free terminal.
OFF
V.MIN
V.MAX
Frame and equipment supplied
The main parts of the appliance are:
• an outer structure in galvanised sheeting, with
mechanical fastening fixings;
• the polystyrene countercurrent type heat exchanger
whose special shape ensures the highest possible
efficiency in terms of heat exchange (up to 92%);
• the two bearing motors with two speed settings;
• 2 x F5 filters.
Installation
The appliance must be installed according to the safety
regulations currently in force in the country of
destination, and the instructions provided in this
manual.
The appliance must be fitted to an internal surface or
wall of the home that is structurally sound enough to
bear its weight (see table).
A
MOD
HRI-One
The appliance must not be installed in areas where the
temperature may drop below 0°C.
The conduits used for carrying ducting must be of the
right size.
The conduits to and from the exterior must be thermally
insulated and not subject to vibration.
The 150/125 mm standard diameter inlet and outlet
pipes (with adapter) must be secured to the
corresponding appliance couplings by means of clips or
other suitable fastening systems.
If the output of the exaust air is on a roof it is mandatory
to use a suitable device designed to avoid the formation
of condensation and rain water infiltrations
if the inlet of supply air is on a roof it is mandatory to use
a suitable device designed to avoid the formation of
condensation and rain water infiltrations
The
appliance
servicing/maintenance purposes. In particular, the false
ceiling in which the appliance is installed must have a
suitably sized inspection hatch, which provides access
to the door protecting the electric/electronic parts and
the filters. This means the appliance does not have to be
removed from the false ceiling during routine
maintenance (filter replacement), nor even some non-
routine procedures (e.g. motorised fan replacement).
Weight of the
Weight of the
appliance
26,5
must
be
easily
Bypass
8,5
accessible
for