Bull NovaScale R480 Guide De L'utilisateur page 251

Publicité

8-18
Code
Message d'erreur
d'erreur
0611
IDE configuration changed.
0613
COM A configuration changed.
0614
COM A config. error - device disabled.
0615
COM B configuration changed.
0616
COM B config. error - device disabled.
0617
Floppy configuration changed.
0618
Floppy config. error - device disabled.
0619
Parallel port configuration changed.
061A
Parallel port config. error - device disabled.
0B00
Rebooted during BIOS boot at Post Code.
0B1B
PCI System Error on Bus/Device/Function.
0B1C
PCI Parity Error on Bus/Device/Function.
0B28
Unsupported Processor detected on Processor 1.
0B29
Unsupported Processor detected on Processor 2.
0B2A
Unsupported Processor detected on Processor 3.
0B2B
Unsupported Processor detected on Processor 4.
0B30
Fan 1 Alarm occurred.
0B31
Fan 2 Alarm occurred.
0B32
Fan 3 Alarm occurred.
0B33
Fan 4 Alarm occurred.
0B34
Fan 5 Alarm occurred.
0B35
Fan 6 Alarm occurred.
0B50
Processor #1 with error taken off line.
0B51
Processor #2 with error taken offline.
0B52
Processor #3 with error taken offline.
0B53
Processor #4 with error taken offline.
0B5F
Forced to use Processor with error
0B60
DIMM group #1 has been disabled
0B61
DIMM group #2 has been disabled
0B62
DIMM group #3 has been disabled
0B63
DIMM group #4 has been disabled
0B64
DIMM group #5 has been disabled
0B65
DIMM group #6 has been disabled
0B66
DIMM group #7 has been disabled
0B67
DIMM group #8 has been disabled
0B70
The error occurred during temperature sensor reading.
0B71
System Temperature out of the range.
0B74
The error occurred during voltage sensor reading.
0B75
System voltage out of the range.
0B78
The error occurred during fan sensor reading
0B7C
The error occurred during redundant power module
confirmation
0B7D
The normal operation can't be guaranteed with use of only
one PSU
0B80
BMC Memory Test Failed.
0B81
BMC Firmware Code Area CRC check failed.
0B82
BMC core hardware failure.
0B83
BMC IBF or OBF check failed.
0B8A
BMC SEL area full.
0B8B
BMC progress check timeout.
0B8C
BMC command access failed.
Action recommandée
Contactez le service client.
Assurez-vous que le serveur prend en charge le
processeur. En cas de doute, contactez le service client
et faites une demande d'intervention.
Une défaillance ou un ralentissement du ventilateur peut
se produire. Contactez le service client et faites une
demande d'intervention.
Les performances du processeur se sont dégradées.
Contactez le service client.
Une erreur étant détectée au niveau de chaque
processeur, le démarrage du système est forcé.
Contactez le service client.
Contactez le service client.
Une défaillance ou un ralentissement du ventilateur peut
se produire. Contactez le service client et faites une
demande d'intervention.
Contactez le service client.
Contactez le service client pour remplacer l'alimentation.
Contactez le service client pour ajouter une alimentation
supplémentaire ou remplacer l'alimentation existante.
Mettez le serveur hors tension puis sous tension pour le
démarrer. Si l'erreur ne peut être corrigée, contactez le
service client.