Troubleshooting

Fault
Uneven movement of the
moving mass
Squeaking noises or
vibrations
vibrations
Fig. 16
12

Technical data

SLTE−...
Design
Mounting position
Maximum forces and
torques
Max. perm. effective load
Horizontal fitting
Vertical fitting
Repetition accuracy
1) Max. permitted speed and effective load depend on each other (see chapter
Characteristic curves")
2) The SLTE in conjunction with controller SFC−DC is intended for use in industrial ap
plications.
Festo SLTE 0910a English
Possible cause
Bearing surfaces dirty
SLTE is fitted distorted
No lubrication
Effective load too large
Speed too high
10
Electric linear drive with rotating spindle
Any
See catalogue specifications
1)
1.5 kg
0.5 kg
0.1 mm
.
Remedy
Clean the bearing surfaces
Rectify distortion
Lubricate SLTE again in
accordance with table in
chapter "Care and
maintenance"
Observe maximum values
as per diagram in chapter
as per diagram in chapter
"Characteristic curves"
16
4 kg
2 kg
39