GB
IE
responsible for accidents causing injury to
other people or damage to property.This
equipment is not suitable for commercial
use. Commercial use will invalidate the
guarantee.
The device is part of the Parkside
X 12 V TEAM series and can be opera-
ted using Parkside X 12 V TEAM series
batteries. The batteries may only be
charged using chargers from the Parkside
X 12 V TEAM series.
General description
The illustrations are on the
front and back fold-out page.
Extent of the delivery
Carefully unpack the appliance and check
that it is complete:
-
Cordless Polisher /Sander
-
Storage case
-
Polishing disc with Velcro
-
2x polishing pad (orange, black)
-
Imitation fur attachment
-
5x sandpaper
-
Instruction Manual
Battery and charger are not included.
Overview
1 Thread socket
2 Spindle stop button
3 Gear selection switch
4 Battery charge indicator
5 Rechargeable battery
6 Release button for rechargeable
battery
7 On/off switch
8 Start lock
9 Polishing disc
20
10 Polishing pad, orange
11 Polishing pad, black
12 Sandpaper
13 Imitation fur
14 Additional handle
15 Charger
16 Storage case
Functional description
The device is intended for waxing and po-
lishing, or sanding. The rotating polishing
disc ensures an even method of operation.
The polishing pads and sandpaper are
easily interchangeable for various appli-
cations.
Please refer to the descriptions below for
information on how the operating elements
work.
Technical data
Cordless Polisher /Sander ..............
PAAP 12 B2
Motor voltage U .......................... 12 V
Rated speed n
1st gear ...........................0-2800 min
2nd gear .........................0-8300 min
Thread socket ................................... M6
Polishing disc diameter ......... max. 75 mm
Weight ................................ ca. 0,65 kg
Sound pressure level
(L
) ................... 70,1 dB(A), K
pA
Sound power level
(L
) ................. 81,1 dB(A); K
WA
Vibration (a
) .....< 2,5 m/s
h
Temperature...........................max. 50 °C
Charging process ...................4 - 40 °C
Operation .......................... -20 - 50 °C
Storage .................................0 - 45 °C
-1
-1
= 3 dB
pA
= 3 dB
WA
2
; K= 1,5 m/s
2