User manual
Tub is not filled
with water
Storage container
contains water
Water consumption in
water-cooled machines is
too high
8. Disposal
8.1 Disposal instructions
If the machine would be put out of service, please follow the instructions below for disposal:
The refrigerant circuit of the ice cube maker contains HFC and lubricants that are harmful
to water!
The machine must therefore be disposed of properly according to the relevant environmental
protection regulations. Should you have no options for proper disposal, please contact your
specialist dealer or WESSAMAT directly.
User-manual-TopLine-v.02
1. Water inlet valve
clogged or soiled
2. Electrical fault in
water inlet valve
3. Water level
sensor affected by a
'moisture bridge'
4. Fault in water
sensor electronics
Drain tube of the storage
container is kinked or
clogged
Flow tub cooling water
controller is too high
Deutsch 4-43 – English 44-79 – Français 80-114
1. Clean pre-screen
2. Check input voltage, replace
water inlet valve if necessary
3. Dry the water level sensor
4. Replace water sensor
electronics
Ensure free water drainage
Readjust or replace cooling water
controller
01/2021
78