I.S. 6.5
50Hz
GB
6.2
Control panel connection
There are two remote control panels available, installable
on the bridge, which can be connected to the generator
for starting and stopping.
Both models are supplied with a 20 m electric connection
cable with a connector fitted at the end.
Fit the connector of the connection cable to the special
coupling located at the lower part of the instrument panel
casing inside the generator (Fig. 16 Ref. 1) and the
opposite part to the remote control panel.
6.3 A.C. Connection
This connection is made through the power terminal
board located on the alternator of the generator (Fig. 14
Ref. 1). This terminal board is accessed after having
removed the closing panel as shown in Fig.13 Ref. 1.
This range of generators may be operated at both 115V
- 50Hz / 120V - 60Hz and 230V - 50Hz / 240V -60Hz.
Hence different connections (and thus uses) are possible
according to the following configurations:
1 - Parallel configuration; in this configuration there are
two output :
- 115V between the points 11 and 6 by connecting the
alternator outputs 1-44 and 3-6 according to the
diagram in Fig. 15 Ref. 1
- 120V between the points 11 and 5 by connecting the
alternator outputs 11-44 and 2-5 according to the
diagram in Fig. 15 Ref. 3.
Use the insulators on the terminal board for the
connection (Fig.14 Ref.2).
2 - Serial connection; in this configuration there are
two output :
- 230V between the points 11 and 6 by connecting the
alternator outputs 3-44 according to the diagram in
Fig. 15 Ref. 2
- 240V between the points 11 and 5 by connecting the
alternator outputs 2-44 according to the diagram in
Fig. 15 Ref. 4
Use the insulators on the terminal board for the
connection (Fig.14 Ref.2).
With the series connection the power may be drawn
simultaneously at a voltage of 115/230 50Hz and 120/
240V 60Hz, as per the diagrams in Fig.15 Ref.5 and 6.
draw a voltage of 115V / 50Hz (Fig.15 Ref. 5) or 120V
/ 60Hz (Fig.15 Ref. 6), the current must not exceed
50% of the rated current.
GB
- 14
- I.S. 7.6
60Hz
If the series connection is used, to
- Use the jumpers on the terminal board (Fig.15
Ref.1,2,3,4) to obtain both the parallel and the series
connections.
- Ensure that the sum of the loads to be fed does not
exceed the rated output of the generator.
- The generator is equipped with a magnetothermal
switch which cuts the power in the event of an overload
or short-circuit.
Table of characteristics for single voltage
Hz
V
115
IS 6.5
50
230
120
IS 7.6
60
240
Table of characteristics for double voltage
Hz
V
115
IS 6.5
50
230
120
IS 7.6
60
240
6.4 Generator - Mains switching
A switch should be placed on the line to switch the user
appliances from the generator to an external power line.
The switch should be dimensioned according to the size
of the loads: a general diagram is shown in fig. 17.
7 LIFTING
For deplacing and lifting of the genset use only the proper
lifting hook.
To hook the genset to places
different from that indicated could cause damages to
the genset itself and became a danger for operators.