Technical Data; General; Resistance To Penetration Of Infectious Agents; Resistance Of The Suit Material - Dräger CPS 7900 Notice D'utilisation

Masquer les pouces Voir aussi pour CPS 7900:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Technical data

9
Technical data
9.1

General

Sizes in cm:
Height
Suit
measure-
size
S
150-165
80-118
M
160-175
80-118
L
170-185
80-118
XL
180-200
104-124
XXL
195-210
104-124
Sizes in inch:
Height
Suit
measure-
size
S
59-65
M
63-69
L
67-73
XL
71-79
XXL
77-83
Weight:
without boots
approx. 5.1 kg
with boots
approx. 6.6 kg
Material:
Suit
D-mex
Visor
Special polyvinyl chloride
Gloves
FKM/butyl or
laminate: HPPE or
K-MEX-Gigant: Para-aramid or
Tricotril: Nitril/para-aramid
Safety boots
Nitrile-P
black, FPA-CR safety boots
Socks
D-mex
Colours:
Outside/inside
blue/grey
orange/grey
olive/grey
beige/grey
Temperatures:
During use
-40 °C to +70 °C
lower temperatures down to -80 °C are
possible during short-term exposure and
tested for the material D-mex by Dräger,
but not as part of the EU type approval
test.
Observe operating temperatures of the
respiratory protective equipment!
During storage
-30 °C to +60 °C
1
tested by Dräger
32
Chest
Waist
measure-
persons
ment
ment
72-106
<80 kg
72-106
>80 kg
72-106
<100 kg
95-110
<120 kg
95-110
<140 kg
Chest
Waist
measure-
persons
ment
ment
31-45
28-41
<175 lb
31-45
28-41
>175 lb
31-45
28-41
<220 lb
41-48
37-43
<265 lb
41-48
37-43
<310 lb
1
9.2
Resistance to penetration of infectious
agents
Test
Resistance to contaminated
liquids under hydrostatic
For
pressure (with the
bacteriophage Phi-X174)
with
Resistance to infectious
agents in the event of
physical contact with
substances containing
contaminated liquids
Resistance to biologically
contaminated dusts
Resistance to biologically
contaminated aerosols
For
1
in accordance with EN 14 126:2003+AC:2005
with
9.3

Resistance of the suit material

Test
Abrasion resistance
Flex-cracking resistance
Flex-cracking resistance at
-30 °C
Tear resistance
Penetration resistance
Resistance to flame
penetration
Seam strength
Tensile strength
1
according to EN 943-1:2015
Result
Category
hydrostatic
6
pressure:
20 kPa
Breakthrough-
6
time: >75 min.
Penetration:
3
<1 log cfu
Penetration:
3
log r endless
Result
Category
>2000 cycles
6
>100000 cycles
6
>4000 cycles
6
>40 N
3
>50 N
3
Self-
3
extinguishing
>500 N
6
>1000 N
6
Dräger CPS 7900
1
1

Publicité

Table des Matières
loading